A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Early diagnosis of Zika infection using a ZnO nanostructures-based rapid electrochemical biosensor. | LitMetric

Early diagnosis of Zika infection using a ZnO nanostructures-based rapid electrochemical biosensor.

Talanta

Centro de Tecnologia da Informação Renato Archer, CTI, Rod. D. Pedro I, KM 143.6, 13069-901, Campinas, SP, Brazil. Electronic address:

Published: October 2019

In this work, we report a develop of electrochemical immunosensor based on ZnO nanostructures immobilized with ZIKV-NS1 antibody on Printed Circuit Board (PCB). ZnO nanostructures were grown on PCB by chemical bath deposition (CDB) and characterized by SEM. ZIKV-NS1 antibody was immobilized on the ZnO nanostructures surface via cystamine and glutaraldehyde. The samples were characterized by Immunofluorescence Confocal Microscopy and FTIR to identify the immobilization of the antibody to the sensor board. The analytical responses of the immunosensor were evaluated by Cyclic Voltammetry (CV). The biosensor developed here allows rapid detection of Zika virus in undiluted urine, without cross reactive with DENV-NS1 antigen, with linear range 0.1  ng mL to 100 ng mL. The limit of detection is lower than 1.00 pg  mL. The biosensor is portable, cost-effectiveness, and simple to use, which makes it ideal for point-of-care applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2019.04.080DOI Listing

Publication Analysis

Top Keywords

zno nanostructures
12
zikv-ns1 antibody
8
early diagnosis
4
diagnosis zika
4
zika infection
4
zno
4
infection zno
4
zno nanostructures-based
4
nanostructures-based rapid
4
rapid electrochemical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!