A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Developed a novel sensor based on fluorescent graft conjugated polymer for the determination of aristolochic acid in traditional Chinese medicine. | LitMetric

Developed a novel sensor based on fluorescent graft conjugated polymer for the determination of aristolochic acid in traditional Chinese medicine.

Spectrochim Acta A Mol Biomol Spectrosc

Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China. Electronic address:

Published: November 2019

A novel fluorescent graft conjugated polymer (poly (2, 5-bis (Polyethylene glycol oxybutyrate)-1, 4-phenylethynylene-alt-1, 4-phenyleneethynylene, PPE-OB-PEG) has been designed and synthesized for the determination of aristolochic acid (AA). The detection conditions and detection characters of PPE-OB-PEG were systematically explored in this work. The fluorescence intensity of PPE-OB-PEG changes with the different concentration of AA. PPE-OB-PEG has a good linear range towards AA from 1.00 × 10 to 8.00 × 10 mol L and the limit of detection (LOD) is 3.00 × 10 mol L (S/N = 3). PPE-OB-PEG have been applied to detect AA in traditional Chinese medicine samples and the results are satisfactory. The experimental results show that PPE-OB-PEG can be used as a fluorescence probe for rapid and sensitive detection of AA.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2019.117239DOI Listing

Publication Analysis

Top Keywords

fluorescent graft
8
graft conjugated
8
conjugated polymer
8
determination aristolochic
8
aristolochic acid
8
traditional chinese
8
chinese medicine
8
ppe-ob-peg
6
developed novel
4
novel sensor
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!