Background: Transthoracic echocardiograms (TTE) performed and interpreted by cardiology fellows during off-duty hours are critical to patient care, however limited data exist on their interpretive accuracy. Our aims were to determine the discordance rate between TTEs performed and interpreted by cardiology fellows and National Board of Echocardiography certified attending cardiologists and to identify factors associated with discordance.

Methods: Consecutive on-call TTEs acquired and interpreted by 1st year cardiology fellows over 4.6 years at an academic center were prospectively evaluated by attending cardiologists. Fellow interpretations were classified as concordant or discordant with the attending interpretation. We assessed the association of patient, imaging and fellow characteristics with discordance.

Results: A total of 777 TTE interpretations (730 patients) were performed/interpreted by 40 first year fellows and overread by 13 attendings. The most common indications were assessment of left ventricular function (40.9%) and pericardial effusion (37.3%). There was a major or minor discordance in 4.1 and 17.4% of studies, respectively with 42.1% of disagreements occurring in assessment of left ventricular size and function. The indication to assess left ventricular function [OR 2.19, 95% CI (1.32, 3.62), P = 0.002 vs. pericardial effusion] and greater duration of echocardiographic image acquisition (OR 1.02, 95% CI 1.01, 1.03, P = 0.004) were independently associated with overall discordance.

Conclusions: In this large prospective study we found that attending cardiologists disagreed with 1 in 5 fellow TTE interpretations. Standardized tools for evaluation of echocardiograms performed by fellows are needed to ensure quality of training and patient safety.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6567532PMC
http://dx.doi.org/10.1186/s12909-019-1634-7DOI Listing

Publication Analysis

Top Keywords

cardiology fellows
16
attending cardiologists
16
left ventricular
12
year cardiology
8
performed interpreted
8
interpreted cardiology
8
tte interpretations
8
assessment left
8
ventricular function
8
fellows
6

Similar Publications

Development and Content Validity of a Questionnaire on Peripheral Intravenous Catheter Maintenance and Knowledge of Nursing Professionals Regarding Best Practices.

J Infus Nurs

January 2025

Author Affiliations: Escola Paulista de Enfermagem, Universidade Federal de São Paulo (EPE-UNIFESP), São Paulo, Brazil (RN Doll); Escola Paulista de Enfermagem, Universidade Federal de São Paulo (EPE-UNIFESP), São Paulo, Brazil (RN Aprile); Escola Paulista de Enfermagem, Universidade Federal de São Paulo (EPE-UNIFESP), São Paulo, Brazil (RN Gonçalves); Programa de Pós-graduação em Ciências Farmacêuticas, Universidade Estadual de Feira de Santana (UEFS), Bahia, Brazil (Prof da Silva); Escola Paulista de Enfermagem, Universidade Federal de São Paulo (EPE-UNIFESP), São Paulo, Brazil (Prof Kusahara); Escola Paulista de Enfermagem, Universidade Federal de São Paulo (EPE-UNIFESP), São Paulo, Brazil (Prof Lopes).

The aims of this study were to develop a questionnaire on peripheral intravenous catheter (PIVC) maintenance, evaluate its content validity, and assess factors influencing the level of knowledge of nursing professionals regarding best practices.The study was conducted in 3 stages: (1) development of a questionnaire on PIVC maintenance; (2) content validity assessment by experts with assessment of comprehensiveness, relevance, and clarity; and (3) application of the questionnaire to 1493 nursing professionals. Relationships between personal characteristics and knowledge levels were evaluated.

View Article and Find Full Text PDF

Deep learning-based aberration compensation improves contrast and resolution in fluorescence microscopy.

Nat Commun

January 2025

Laboratory of High Resolution Optical Imaging, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland, USA.

Optical aberrations hinder fluorescence microscopy of thick samples, reducing image signal, contrast, and resolution. Here we introduce a deep learning-based strategy for aberration compensation, improving image quality without slowing image acquisition, applying additional dose, or introducing more optics. Our method (i) introduces synthetic aberrations to images acquired on the shallow side of image stacks, making them resemble those acquired deeper into the volume and (ii) trains neural networks to reverse the effect of these aberrations.

View Article and Find Full Text PDF

Rapid identification and phenotyping of nonalcoholic fatty liver disease patients using a machine-based approach in diverse healthcare systems.

Clin Transl Sci

January 2025

Division of Digestive and Liver Diseases, Department of Medicine, Center for Liver Disease and Transplantation, Columbia University Irving Medical Center, New York, New York, USA.

Nonalcoholic fatty liver disease (NAFLD) is the most common global cause of chronic liver disease and remains under-recognized within healthcare systems. Therapeutic interventions are rapidly advancing for its inflammatory phenotype, nonalcoholic steatohepatitis (NASH) at all stages of disease. Diagnosis codes alone fail to recognize and stratify at-risk patients accurately.

View Article and Find Full Text PDF

Apoptotic clearance by stem cells: molecular mechanisms for recognition and phagocytosis of dead cells.

Signal Transduct Target Ther

December 2024

Department of Cardiology, Angiology, Hemostaseology and Medical Intensive Care, Medical Faculty Mannheim, University Medical Centre Mannheim (UMM), Heidelberg University, 68167, Mannheim, Germany.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!