Bacterial contamination of automated MRI contrast injectors in clinical routine.

GMS Hyg Infect Control

Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Germany.

Published: May 2019

To quantify the frequency of bacterial contamination of the injected contrast agent/saline solution by an automated contrast injection system, and to evaluate whether usage of a novel tube system can reduce it. For bacterial contamination quantification two identical automated piston pump MRI contrast injectors were used in combination with a standard tube system. 3-5 ml of the contrast agent/saline solution was collected from the system prior to its connection to the patients' venous cannula in 104 consecutive patients. To test, whether a novel tube system reduces contamination, a tube system with shielded screw connections was used with the same contrast injectors and contrast agent/saline samples were collected in further 101 patients. Specimens were microbiologically analyzed. Frequencies of contamination were compared using Fisher exact test. With the standard tube system, bacterial contamination was observed in 5.8% (6 out of 104 specimens). With the novel tube system, contamination was observed in 2.0% (2 out of 101 specimens, p=0.280). was the most common germ (5 cases) followed by (2 cases) and (1 case). Bacterial contaminations of MRI contrast injectors occurred in a non-negligible frequency especially with . A trend towards reduced bacterial contamination was seen when a novel tube system with shielded screw connections was used.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6545436PMC
http://dx.doi.org/10.3205/dgkh000321DOI Listing

Publication Analysis

Top Keywords

tube system
28
bacterial contamination
20
contrast injectors
16
novel tube
16
mri contrast
12
contrast agent/saline
12
system
9
contrast
8
agent/saline solution
8
standard tube
8

Similar Publications

Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.

Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.

View Article and Find Full Text PDF

Sapphire fiber Bragg gratings (SFBGs) are promising high-temperature sensors in many harsh environments, such as aviation, nuclear power, and furnaces. Here, we proposed and experimentally demonstrated a quasi-distributed high-temperature sensor based on an SFBG array sealed in an argon gas-infiltrated sapphire tube interrogated by using an InGaAs-based interrogator. An SFBG array including five SFBGs was inscribed using the femtosecond laser line-by-line method and sealed in an argon gas-infiltrated sapphire tube.

View Article and Find Full Text PDF

Role of Leucine-Rich Repeat-Containing G-Protein-Coupled Receptors 4-6 (LGR4-6) in the Ovary and Other Female Reproductive Organs: A Literature Review.

Cell Transplant

January 2025

Department of Obstetrics and Gynecology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Tzu Chi University, Hualien.

Leucine-rich repeat-containing G-protein-coupled receptors regulate stem cell activity and tissue homeostasis within female reproductive organs, primarily through their interaction with the Wnt/β-catenin signaling pathway. LGR4-6 are increasingly recognized for their roles in organ development, regeneration, and cancer. This review aims to provide a comprehensive overview of the roles of LGR4-6 in female reproductive organs, highlighting their significance in normal physiology and disease states, specifically in the context of ovarian cancer.

View Article and Find Full Text PDF

Objective: We aimed to evaluate and compare the rise in the temperature for the safety of the ureter and kidney parenchyma when firing the holmium laser and the thulium fiber laser (TFL).

Methods: We performed a laboratory experiment to measure the rise in temperature upon firing holmium laser and a TFL in a 10 cm3 transparent test tube in an outdoor environment and then in a container with normal saline.

Results: In a 10 cc test tube with static water at 25°C, the rise in temperature with holmium and TFL depends on the firing time, keeping power constant.

View Article and Find Full Text PDF

Introduction Congenital malformations are a major cause of perinatal morbidity and mortality in developing countries and are assuming greater importance than ever before. They affect a variety of organ systems and various etiologies have been identified in literature including Toxoplasmosis, Other (syphilis, varicella-zoster, parvovirus B19), Rubella, Cytomegalovirus, Herpes Simplex (TORCH) infections, exposure to pollutants, consumption of tobacco and alcohol, and advanced maternal age. In developing countries, diagnosis is frequently delayed which leads to poorer outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!