  • Endovascular therapy for peripheral arterial disease often leads to high restenosis rates due to challenging mechanical stresses from leg movements.
  • Researchers hypothesized that blood flow dynamics during leg flexion contribute to restenosis, conducting personalized computational fluid dynamics (CFD) analyses on 20 patients post-intervention.
  • The study found that severe arterial deformations from flexion created adverse blood flow conditions, which predicted restenosis with 75% accuracy, emphasizing the need for improved imaging techniques to better understand blood flow changes in stented arteries.

Article Abstract

Endovascular therapy in patients suffering from peripheral arterial disease shows high rates of restenosis. The poor clinical outcomes are commonly explained by the demanding mechanical environment due to leg movements, but the mechanisms responsible for restenosis remain unknown. In this study, we hypothesized that restenosis following revascularization is associated with hemodynamical markers derived from blood flow during leg flexion. Therefore, we performed personalized computational fluid dynamics (CFD) analyses of 20 patients, who underwent routine endovascular femoro-popliteal interventions. The CFD analyses were conducted using 3D models of the arterial geometry in straight and flexed positions, which were reconstructed from 2D angiographic images. Based on restenosis rates reported at 6-month follow-up, logistic regression analyses were performed to predict restenosis from hemodynamical parameters. Results showed that severe arterial deformations, such as kinking, induced by leg flexion in stented arteries led to adverse hemodynamic conditions that may trigger restenosis. A logistic regression analysis based solely on hemodynamical markers had an accuracy of 75%, which showed that flow parameters are sufficient to predict restenosis (p = 0.031). However, better predictions were achieved by adding the treatment method in the model. This suggests that a more accurate image acquisition technique is required to capture the localized modifications of blood flow following intervention, especially around the stented artery. This approach, based on the immediate postoperative configuration of the artery, has the potential to identify patients at increased risk of restenosis. Based on this information, clinicians could take preventive measures and more closely follow these patients to avoid complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6825029PMC
http://dx.doi.org/10.1007/s10237-019-01183-9DOI Listing

Publication Analysis

Top Keywords

hemodynamical markers
12
leg flexion
12
restenosis based
8
restenosis
8
blood flow
8
cfd analyses
8
logistic regression
8
predict restenosis
8
based
5
prediction restenosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!