Background: The aim of A MAastricht Contrast-Induced Nephropathy Guideline (AMACING) trial was to evaluate non-inferiority of no prophylaxis compared to guideline-recommended prophylaxis in preventing contrast induced nephropathy (CIN), and to explore the effect on long-term post-contrast adverse outcomes. The current paper presents the long-term results.

Methods: AMACING is a single-centre, randomised, parallel-group, open-label, phase 3, non-inferiority trial in patients with estimated glomerular filtration rate [eGFR] 30-59 mL/min/1.73 m combined with risk factors, undergoing elective procedures requiring intravenous or intra-arterial iodinated contrast material. Exclusion criteria were eGFR < 30 mL/min/1.73 m, dialysis, no referral for prophylaxis. The outcomes dialysis, mortality, and change in renal function at 1 year post-contrast were secondary outcomes of the trial. Subgroup analyses were performed based on pre-defined stratification risk factors. AMACING is registered with ClinicalTrials.gov: NCT02106234.

Findings: From 28,803 referrals, 1120 at-risk patients were identified. 660 consecutive patients agreed to participate and were randomly assigned (1:1) to no prophylaxis (n = 332) or standard prophylactic intravenous hydration (n = 328). Dialysis and mortality data were available for all patients. At 365 days post-contrast dialysis was recorded in two no prophylaxis (2/332, 0.60%), and two prophylaxis patients (2/328, 0.61%; p = 0.9909); mortality was recorded for 36/332 (10.84%) no prophylaxis, and 32/328 (9.76%) prophylaxis patients (p = 0.6490). The hazard ratio was 1.118 (no prophylaxis prophylaxis) for one-year risk of death (95% CI: 0.695 to 1.801, p = 0.6449). The differences in long-term changes in serum creatinine were small between groups, and gave no indication of a disadvantage for the no-prophylaxis group.

Interpretation: Assuming optimal contrast administration, not giving prophylaxis to elective patients with eGFR 30-59 mL/min/1.73 m is safe, even in the long-term.

Funding: Stichting de Weijerhorst.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6537536PMC
http://dx.doi.org/10.1016/j.eclinm.2018.10.007DOI Listing

Publication Analysis

Top Keywords

iodinated contrast
8
contrast material
8
prophylactic intravenous
4
intravenous hydration
4
hydration protect
4
protect renal
4
renal function
4
function intravascular
4
intravascular iodinated
4
material amacing
4

Similar Publications

Photon-counting mammography is an emerging modality that allows for spectral imaging and provides a differentiation of material compositions. The development of photon-counting mammography-specific contrast agents has yet to be explored. In this study, the contrast, sensitivity, and organ dose between silver sulfide nanoparticles (AgS-NPs) and a clinically approved iodinated agent (iopamidol) were investigated using a contrast-embedded gradient ramp phantom and a prototype scanner.

View Article and Find Full Text PDF

Background: To define optimal parameters for the evaluation of vessel visibility in intracranial stents (ICS) and flow diverters (FD) using photon-counting detector computed tomography angiography (PCD-CTA) with spectral reconstructions.

Methods: We retrospectively analyzed consecutive patients with implanted ICS or FD, who received a PCD-CTA between April 2023 and March 2024. Polyenergetic, virtual monoenergetic, pure lumen, and iodine reconstructions with different keV levels (40, 60, and 80) and reconstruction kernels (body vascular [Bv]48, Bv56, Bv64, Bv72, and Bv76) were evaluated by two radiologists with regions of interests and Likert scales.

View Article and Find Full Text PDF

Coronary artery disease (CAD) remains a leading cause of morbidity and mortality worldwide, necessitating advancements in diagnostic techniques. Coronary CT angiography (CCTA) has emerged as a pivotal non-invasive tool for evaluating coronary artery anatomy and detecting atherosclerotic plaque burden with high spatial resolution. This review explores the evolution of CCTA, highlighting its technological advancements, clinical applications, and challenges.

View Article and Find Full Text PDF

Background: K-edge subtraction (KES) imaging is a dual-energy imaging technique that enhances contrast by subtracting images taken with x-rays that are above and below the K-edge energy of a specified contrast agent. The resulting reconstruction spatially identifies where the contrast agent accumulates, even when obscured by complex and heterogeneous distributions of human tissue. This method is most successful when x-ray sources are quasimonoenergetic and tunable, conditions that have traditionally only been met at synchrotrons.

View Article and Find Full Text PDF

Population-level impact of COVID-19 on thyroid function tests: Results from a repeated cross-sectional study.

J Infect Public Health

January 2025

Department of Genomic Medicine, Division of Biochemistry, Molecular Biology, and Nutrition, University Hospital of Nancy, Nancy F-54000, France; Reference Center for Inborn Errors of Metabolism (ORPHA67872), University Hospital of Nancy, Nancy F-54000, France; Faculty of Medicine of Nancy, University of Lorraine, Nancy F-54000, France; INSERM UMR_S 1256, Nutrition, Genetics, and Environmental Risk Exposure (NGERE), Nancy F-54000, France. Electronic address:

Purpose: Reports have highlighted thyroid abnormalities, including subacute thyroiditis and thyrotoxicosis, in COVID-19 patients, with a potential link between thyroid dysfunction and disease severity. However, population-level studies on COVID-19's impact on thyroid hormone levels are limited. We aimed to assess the impact of the COVID-19 pandemic on thyroid function tests at the population level.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!