Introduction: Traditionally, fluoroscopy and postoperative computed tomographic (CT) scans are used to evaluate screw position after pediatric cervical spine fusion. However, noncontained screws detected postoperatively can require revision surgery. Intraoperative O-arm is a 3-dimensional CT imaging technique, which allows intraoperative evaluation of screw position and potentially avoids reoperations because of implant malposition. This study's objective was to evaluate the use of intraoperative O-arm in determining the accuracy of cervical implants placed by a free-hand technique using anatomic landmarks or fluoroscopic guidance in pediatric cervical spine instrumentation.

Methods: A single-center retrospective study of consecutive examinations of children treated with cervical spine instrumentation and intraoperative O-arm from 2014 to 2018 was performed. In total, 44 cases (41 children, 44% men) with a mean age of 11.9 years (range, 2.1 to 23.5 y) were identified. Instability (n=16, 36%) and deformity (n=10, 23%) were the most frequent indications. Primary outcomes were screw revision rate, neurovascular complications caused by noncontained screws, and radiation exposure.

Results: A total of 272 screws were inserted (60 occipital and 212 cervical screws). All screws were evaluated on fluoroscopy as appropriately placed. Four screws (1.5%) in 4 cases (9%) were noncontained on O-arm imaging and required intraoperative revision. A mean of 7.7 levels (range, 5 to 13) were scanned. The mean CT dose index and dose-length product were 15.2±6.87 mGy and 212.3±120.48 mGy×cm. Mean effective dose was 1.57±0.818 mSv. There was no association between screw location and noncontainment (P=0.129). No vertebral artery injuries, dural injuries, or neurologic deficits were related to the 4 revised screws.

Conclusions: Intraoperative non-navigated O-arm is a safe and efficient method to evaluate screw position in pediatric patients undergoing cervical spine instrumentation. Noncontained screws were detected in 9% of cases (n=4). O-arm delivers low radiation doses, allows for intraoperative screw revision, and negates the need for postoperative CT scans after confirmation of optimal implant position.

Level Of Evidence: Level IV.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BPO.0000000000001416DOI Listing

Publication Analysis

Top Keywords

cervical spine
20
intraoperative o-arm
16
pediatric cervical
12
screw position
12
noncontained screws
12
intraoperative
8
evaluate screw
8
position pediatric
8
screws detected
8
allows intraoperative
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!