Leadless solution for arrhythmia-related sudden unexpected death in epilepsy.

Proc (Bayl Univ Med Cent)

Division of Cardiovascular Medicine and Surgery, The Center for Comprehensive Cardiovascular Care (C4), St. Louis University Hospital and School of MedicineSt. LouisMissouri.

Published: April 2019

A leadless pacemaker is a recently approved pacing technology that helps mitigate lead-related complications, but it has several limitations. Careful candidate selection is needed. Here, we demonstrate leadless pacing as the solution for prolonged postictal bradycardia/asystole; there is no consensus regarding pacemaker implantation for seizure patients with such a risk of sudden cardiac death.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6541047PMC
http://dx.doi.org/10.1080/08998280.2018.1550338DOI Listing

Publication Analysis

Top Keywords

leadless solution
4
solution arrhythmia-related
4
arrhythmia-related sudden
4
sudden unexpected
4
unexpected death
4
death epilepsy
4
epilepsy leadless
4
leadless pacemaker
4
pacemaker approved
4
approved pacing
4

Similar Publications

Sarcoidosis is a complex disease characterized by inflammatory granulomas that can affect various organs, including the heart. The diagnosis of cardiac sarcoidosis poses challenges, and current criteria involve the use of advanced imaging techniques and histological confirmation. Clinical manifestations of cardiac sarcoidosis vary widely, ranging from heart block to ventricular tachycardia and heart failure.

View Article and Find Full Text PDF

Device-device interference triggered by an abandoned pacemaker: a case report.

Eur Heart J Case Rep

November 2024

Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Carl-Neuberg-Straße 1, Hannover 30625, Germany.

Article Synopsis
  • Cardiac implantable electronic devices (CIEDs) can experience electromagnetic interference from various sources, including household and medical equipment, which can lead to malfunctions.
  • A 79-year-old man experienced presyncope due to his abandoned abdominal pacemaker reactivating and interfering with his active leadless pacemaker, resulting in pacing problems and symptoms.
  • The situation was managed by adjusting the active pacemaker's settings, but ultimately the best solution was to remove the abandoned pacemaker to prevent further complications.
View Article and Find Full Text PDF

. Endovascular brain-computer interfaces (eBCIs) offer a minimally invasive way to connect the brain to external devices, merging neuroscience, engineering, and medical technology. Currently, solutions for endovascular electrocorticography (ECoG) include a stent in the brain with sensing electrodes, a chest implant to accommodate electronic components to provide power and data telemetry, and a long (tens of centimeters) cable travel through vessels with a set of wires in between.

View Article and Find Full Text PDF

Aims: Leadless pacing is a safe and effective alternative to transvenous pacing for bradycardia. Micra AV is a leadless, single-device solution that provides atrioventricular synchronous ventricular pacing therapy. Early results from the Micra AV CED study showed reductions in short-term complications associated with the Micra AV leadless pacemaker among US Medicare patients.

View Article and Find Full Text PDF

Isolated persistent left superior vena cava (PLSVC) is a rare congenital anomaly typically found incidentally due to its asymptomatic nature. However, it can present technical challenges for device implanters. We report a case involving a patient with PLSVC, for whom the implantation of a transcatheter pacing system proved to be the most effective long-term solution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!