A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of Different Apex Locators in Teeth with Simulated Apical Root Resorption: an In Vitro Study. | LitMetric

Background: Accurate working length (WL) determination is necessary in achieving optimal healing by non-surgical root canal therapy in teeth with inflammatory apical root resorption. Electronic apex locators (EALs) are one of the mainstays in determination of WL of teeth.

Aim: This study evaluated the accuracy of three EALs [RootZX (third generation), iPex (fourth generation) and Raypex 6 (modification of a fifth generation)] in determining the WL of teeth with simulated apical root resorption in permanent teeth.

Materials And Methods: Forty freshly extracted maxillary anterior teeth were collected and a 45° oblique cut was made at the root apex with a disc to simulate apical root resorption. Actual working length (AWL) was determined by direct visual method and was used as a control. Electronic working length (EWL) values were measured by three different apex locators that are RootZX (Group I), iPex (Group II) and Raypex 6 (Group III) at apex, 0.5 mm and 1 mm from apex. All values obtained were tabulated and statistical evaluation was carried out.

Results: At apex, EWL obtained using iPex (p=0.05) showed a statistically significant difference from AWL. At 0.5 mm and 1.0 mm tolerance, iPex showed non-acceptability for WL measurement in 67.5% and 17.5% of samples compared to Root ZX (12.5% and 2.5%) and Raypex (7.5% and none) respectively.

Conclusion: Within the limitation of this study, it can be concluded that Raypex 6 and RootZX show statistically significant accuracy in WL measurement compared with iPex in teeth with apical root resorption.

Download full-text PDF

Source
http://dx.doi.org/10.2478/folmed-2018-0033DOI Listing

Publication Analysis

Top Keywords

apical root
20
root resorption
20
apex locators
12
working length
12
teeth simulated
8
simulated apical
8
root
8
apex
6
teeth
5
apical
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!