Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background A novel bioresorbable scaffold, the sirolimus-eluting Fantom, incorporates a radiopaque polymer, struts with a thickness of 125 µm, and a crossing profile of 1.35 mm. The purpose of this study was to evaluate the 9-month angiographic and 12-month clinical outcomes of the FANTOM scaffold in a larger patient population. Methods and Results The FANTOM II study (Safety & Performance Study of the Fantom Sirolimus-Eluting Bioresorbable Coronary Scaffold - First Report on Initial 24 Month Outcomes) was a prospective, multicenter trial which enrolled 240 patients with single de novo coronary stenosis with reference vessel diameter 2.5 to 3.5 mm diameter and lesion length ≤20 mm. Major adverse cardiac events through 12-month follow-up were assessed. Angiographic follow-up was performed in consecutive patient cohorts at 6 months (n=117) and 9 months (n=123). Acute delivery success, acute technical success, acute procedural success, and clinical procedural success rates as defined in the clinical protocol were 97.9% (235/240), 95.8% (230/240), 99.1% (228/230), and 99.6% (227/228), respectively. The mean in-stent late lumen loss at 6 months and 9 months were 0.25±0.40 mm and 0.33±0.36 mm, respectively, and in-segment binary restenosis occurred in 2.0% and 7.6% of patients, respectively. Major adverse cardiac events and target lesion failure through 12 months occurred in 4.2% of 240 patients; scaffold thrombosis developed in only one patient (0.4%). Conclusions The Fantom sirolimus-eluting bioresorbable coronary scaffold demonstrated favorable safety and effectiveness performance at 12-month follow-up. Longer-term follow-up is ongoing to examine the late outcomes with this novel device. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT02539966.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCINTERVENTIONS.118.007283 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!