A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Current phototherapy practice on Java, Indonesia. | LitMetric

Current phototherapy practice on Java, Indonesia.

BMC Pediatr

Department of Pediatrics, Beatrix Children's Hospital, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands.

Published: June 2019

Background: In Indonesia, the burden of severe hyperbilirubinemia is higher compared to other countries. Whether this is related to ineffective phototherapy (PT) is unknown. The aim of this study is to investigate the performance of phototherapy devices in hospitals on Java, Indonesia.

Methods: In 17 hospitals we measured 77 combinations of 20 different phototherapy devices, with and without curtains drawn around the incubator/crib. With a model to mimic the silhouette of an infant, we measured the irradiance levels with an Ohmeda BiliBlanket Meter II, recorded the distance between device and model, and compared these to manufacturers' specifications.

Results: In nine hospitals the irradiance levels were less than required for standard PT: < 10 μW/cm/nm and in eight hospitals irradiance failed to reach the levels for intensive phototherapy: 30 μW/cm/nm. Three hospitals provided very high irradiance levels: > 50 μW/cm/nm. Half of the distances between device and model were greater than recommended. Distance was inversely correlated with irradiance levels (R = 0.1838; P < 0.05). The effect of curtains on irradiance levels was highly variable, ranging from - 6.15 to + 15.4 μW/cm2/nm, with a mean difference (SD) of 1.82 (3.81) μW/cm2/nm (P = 0.486).

Conclusions: In half of the hospitals that we studied on Java the levels of irradiance are too low and, in some cases, too high. Given the risks of insufficient phototherapy or adverse effects, we recommend that manufacturers provide radiometers so hospitals can optimize the performance of their phototherapy devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6555918PMC
http://dx.doi.org/10.1186/s12887-019-1552-1DOI Listing

Publication Analysis

Top Keywords

irradiance levels
12
phototherapy devices
8
device model
8
current phototherapy
4
phototherapy practice
4
practice java
4
java indonesia
4
indonesia background
4
background indonesia
4
indonesia burden
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!