Measurement of the magnetic susceptibility of subtle paramagnetic solutions using the diamagnetic repulsion of polymer microparticles.

Lab Chip

Department of Biomedical Engineering, School of Life Sciences, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Eonyang-eup, Ulju-gun, Ulsan 44919, Republic of Korea.

Published: July 2019

Herein, we described a microfluidic device that enabled the measurement of magnetic susceptibility of a subtle paramagnetic solution that could not be determined by conventional magnetic susceptibility measurement methods such as a superconducting quantum interference device (SQUID). We measured the diamagnetic repelling velocity of polystyrene microparticles suspended in a weak paramagnetic solution including 50-150 mM of gadolinium-diethylenetriamine penta-acetic acid (GD-DTPA) and superparamagnetic iron oxide nanoparticles (SPION) (10 nm in diameter) dispersed in distilled water at various concentrations. The measured diamagnetic repelling velocities correlated with our prediction and also with the magnetic susceptibility of the SPION solution measured by a SQUID magnetometer. Via this approach, we could determine the magnetic susceptibility of the subtle paramagnetic solution of GD-DTPA that could not be measured via the conventional method. This study provides us with the new capability of analyzing weakly paramagnetic solutions such as paramagnetic components or metal contaminants present in environmental liquid samples at low concentrations.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c9lc00245fDOI Listing

Publication Analysis

Top Keywords

magnetic susceptibility
20
susceptibility subtle
12
subtle paramagnetic
12
paramagnetic solution
12
measurement magnetic
8
paramagnetic solutions
8
measured diamagnetic
8
diamagnetic repelling
8
paramagnetic
6
susceptibility
5

Similar Publications

Comparison of DWI techniques in patients with epidermoid cyst: TGSE-BLADE DWI vs. SS-EPI DWI.

Jpn J Radiol

December 2024

Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawaharacho, Kyoto, 6068507, Japan.

Purpose: To compare quantitative values and image quality between single-shot echo-planar imaging (SS-EPI) diffusion-weighted imaging (DWI) and two-dimensional turbo gradient- and spin-echo DWI with non-Cartesian BLADE trajectory (TGSE-BLADE DWI) in patients with epidermoid cyst.

Methods: Patients with epidermoid cyst who underwent both SS-EPI DWI and TGSE-BLADE DWI were included in this study. Two raters placed ROIs encircling the entire epidermoid cyst on SS-EPI DWI, and then on TGSE-BLADE DWI.

View Article and Find Full Text PDF

Cerebral microbleeds (CMB) represent a feature of cerebral small vessel disease (cSVD), a prominent vascular contributor to age-related cognitive decline, dementia, and stroke. They are visible as spherical hypointense signals on T2*- or susceptibility-weighted magnetic resonance imaging (MRI) sequences. An increasing number of automated CMB detection methods being proposed are based on supervised deep learning (DL).

View Article and Find Full Text PDF

Currently, the main limitations of Pd-coated Nb-TiFe dual-phase alloys include insufficient hydrogen permeability, susceptibility to hydrogen embrittlement (HE), and poor tolerance of HS poisoning. To address these issues, this study proposes a series of improvements. First, a novel NbTiFe alloy composed of a well-aligned Nb-TiFe eutectic was successfully prepared using directional solidification (DS) technology.

View Article and Find Full Text PDF

Carbapenem-Resistant Adherence to Magnetic Nanoparticles.

Nanomaterials (Basel)

December 2024

Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI 48824, USA.

Carbapenem-resistant (CRE) is an emerging global concern. Specifically, carbapenemase-producing (CP) strains in CRE have recently been found in clinical, environmental, and food samples worldwide, causing many hospitalizations and deaths. Their rapid identification and characterization are paramount in control, management options, and treatment choices.

View Article and Find Full Text PDF

Direct-drive servo systems are extensively applied in biomimetic robotics and other bionic applications, but their performance is susceptible to uncertainties and disturbances. This paper proposes an adaptive disturbance rejection Zeta-backstepping control scheme with adjustable damping ratios to enhance system robustness and precision. An iron-core permanent magnet linear synchronous motor (PMLSM) was employed as the experimental platform for the development of a dynamic model that incorporates compensation for friction and cogging forces.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!