Effect of Crown Preparation Height on Retention of a Prefabricated Primary Posterior Zirconia Crown.

Pediatr Dent

is an associate professor, Department of Prosthodontics, Loma Linda University, Loma Linda, all in Calif., USA.

Published: May 2019

The purpose of this study was to evaluate the retention strength of prefabricated zirconia crowns for primary teeth with various crown preparation heights. Seventy-five extracted human teeth were prepared to have remaining occluso-cervical heights (OCH) of one mm, two mm, three mm, and four mm. Prefabricated posterior zirconia crowns (EZCrown) were cemented with glass ionomer cement. All groups were thermocycled, except for the nonthermocycled control group, which had three mm OCH. Instron E3000 was used for the pullout test. One-way analysis of variance (ANOVA) with Least Significant Difference post hoc test (P<0.05) were performed. The means for the one-mm, two-mm, three-mm, and four-mm thermocycled groups were 1.7±1.0 MPa, 2.9±1.4 MPa, 3.1±0.7 MPa, and 3.3.0±0.6 MPa, respectively. The mean for the nonthermocycled control three-mm group was 2.7±0.8MPa. A significant difference in retention within the four thermocycled groups was observed (one-way ANOVA, P<0.001). The zirconia crown retention force is closely related to occluso-cervical heights. Two millimeters OCH is crucial for prefabricated zirconia crown retention. (Pediatr Dent 2019;41(3):229-33) Received November 14, 2018 | Last Revision February 25, 2019 | Accepted March 5, 2019.

Download full-text PDF

Source

Publication Analysis

Top Keywords

crown preparation
8
posterior zirconia
8
zirconia crowns
8
preparation height
4
height retention
4
retention prefabricated
4
prefabricated primary
4
primary posterior
4
zirconia crown
4
crown purpose
4

Similar Publications

Background/purpose: SimEx-Plus (EPED. Inc) was already a mature augmented reality (AR) dental training simulator that allowed students to have a high quality dental education practice. Now the EPCAD software has been further developed into a comprehensive computer-aided design software.

View Article and Find Full Text PDF

Background/purpose: The accuracy of intraoral scanners (IOSs) plays a crucial role in the success of final restorations in digital workflows. Previous studies have shown that numerous factors affect the accuracy of IOSs. Most studies have evaluated the accuracy of IOS under one restoration condition.

View Article and Find Full Text PDF

Effect of scan path on accuracy of complete arch intraoral scan.

J Adv Prosthodont

December 2024

Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea.

Purpose: This study aimed to compare the accuracy of an alternative scan path with that of traditional scan paths to obtain a more accurate method for complete arch scans.

Materials And Methods: A mandibular stone cast, including tooth preparations for the inlay, crown, and fixed prosthesis, was scanned 10 times using four different scan paths (A, B, C, and D). The scans were converted into stereolithography files, resized, and superimposed onto a control file obtained from a desktop scanner.

View Article and Find Full Text PDF

Background: Endodontic treatment aims in the preservation of extremely carious primary teeth. For root canal therapy to be successful, root canals must be properly prepared and effectively irrigated .Therefore, it is necessary to select the proper root canal disinfection method to preserve the primary tooth.

View Article and Find Full Text PDF

Objectives: To explore the perspectives of stakeholders on the General Pharmaceutical Council's revised Standards for the Initial Education and Training of Pharmacists that enable pharmacists to prescribe at the point of registration, from 2026.

Methods: This qualitative study used the Theoretical Domains Framework (TDF) to develop schedules for structured interviews that were conducted with various stakeholders and recorded via Microsoft Teams. Recordings were transcribed verbatim, checked for accuracy, and then analysed using the Framework approach, facilitated by NVIVO® software.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!