Background: Hamstring tendon autografts are commonly used for primary anterior cruciate ligament (ACL) reconstruction. Some patients have small hamstring tendons however, which may compromise the clinical outcome of the autograft. To solve this problem, many surgeons use hybrid grafting that involves augmentation of small hamstring autografts with allograft tissue.

Purpose/hypothesis: The purpose was to compare the clinical outcomes between primary ACL reconstructions performed with hamstring autografts and those performed with hybrid grafts in terms of patient-reported evaluation, failure rate, and knee stability. The hypothesis was that primary ACL reconstruction performed with hamstring autograft alone will not differ significantly from that performed with a hybrid graft in terms of patient-reported evaluation, failure rate, or knee stability.

Study Design: Systematic review.

Methods: A systematic review was performed to identify prospective and retrospective comparative studies and cohort studies (evidence levels 1-3) comparing outcomes of primary ACL reconstructions performed with hamstring autografting alone and hybrid grafting. Outcomes included patient-reported evaluation, failure rate, and knee stability.

Results: Ten studies were included: 1 of level 2 and 9 of level 3. Collectively, they included 398 autografts and 341 hybrid grafts. Mean respective follow-up durations ranged from 24.0 to 69.6 months and from 24.0 to 70.8 months. Patient-reported evaluations, including Lysholm, Tegner, and subjective International Knee Documentation Committee scores, were reported in 8 of 10 studies. Failure rates were reported in all 10 studies. Results of knee stability examinations-including KT-1000 arthrometer measurements, the pivot-shift test, Lachman test, and overall International Knee Documentation Committee results-were reported in 4 of 10 studies. In this review, there were no statistically significant differences between autografts and hybrid grafts in terms of patient-reported evaluations, failure rates, or KT-1000 measurements.

Conclusion: In this systematic review, there was no significant difference in patient-reported evaluation or failure rate between primary ACL reconstructions performed with autografts alone and those performed with hybrid grafts. Whether there is a substantial difference in knee stability examination results between autografts and hybrid grafts remains unknown, given a relative lack of reports on knee stability.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0363546519849483DOI Listing

Publication Analysis

Top Keywords

hybrid grafts
20
primary acl
16
patient-reported evaluation
16
evaluation failure
16
failure rate
16
knee stability
16
systematic review
12
acl reconstructions
12
reconstructions performed
12
performed hamstring
12

Similar Publications

Background: Closed head injury (CHI) provokes a prominent neuroinflammation that may lead to long-term health consequences. Microglia plays pivotal and complex roles in neuroinflammation-mediated neuronal insult and repair following CHI. We previously reported that induced neural stem cells (iNSCs) can block the effects of CXCL12/CXCR4 signaling on NF-κB activation in activated microglia by CXCR4 overexpression.

View Article and Find Full Text PDF

Experimental and Theoretical Study of Two 3D Difunctional Electrocatalytic Hybrid Vanadate-Containing Metal-Organic Motifs.

Inorg Chem

January 2025

Key Laboratory of Polyoxometalate Science of Ministry of Education, Faculty of Chemistry, Northeast Normal University, Changchun, Jilin 130024, PR China.

Two novel 3D inorganic-organic hybrids based on [VO]/[VO] clusters, [Cu(bbpy)(VO)]·3HO () and [CuAg(pty)(VO)]·HO () (bbpy = 3,5-bis(1-benzimidazole) pyridine, pty = 4'-(4″-pyridyl)-2,2':6',2″-terpyridine), were isolated in the same POV/Cu/N-heterocycle ligand reaction systems. Hybrids and possess novel three-dimensional bimetallic frameworks derived from [VO]/[VO] clusters and Cu-organic complexes. In , bbpy ligands are grafted by Cu to a grid ribbon 2D sheet, which are connected with benzene-like [VO] to yield a 3D framework.

View Article and Find Full Text PDF

Blunt thoracic aortic injury treated with thoracic endovascular aortic repair in hybrid emergency room: A case report.

Trauma Case Rep

February 2025

Department of Emergency and Critical Care Medicine, Hyogo Emergency Medical Center, 1-3-1 Wakinohamakaigandori, Chuo-ku, Kobe, Hyogo 651-0073, Japan.

Background: Hybrid emergency rooms (ERs) allow computed tomography (CT) scanning, interventional radiology, and surgery all in the same suite. Severe trauma patients with blunt thoracic aortic injury (BTAI) require rapid diagnosis and treatment. Hybrid ERs allow the potential for clinicians to implement multiple therapeutic procedures, including thoracic endovascular aortic repair (TEVAR), for these types of conditions without the need to transport the patients.

View Article and Find Full Text PDF

Objective: Both the en bloc island technique and the branched graft technique (BGT) present advantages but also limitations in aortic arch surgery. Here is the first presentation of an innovative prosthesis for aortic arch replacement, conceived to overcome the disadvantages of both techniques.

Methods: The novel ISLAND graft is a tubular Dacron or hybrid prosthesis with an additional extended Dacron graft ("bubble") on the superior aspect, for en bloc island graft anastomosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!