The effect of column packing procedure on column end efficiency and on bed heterogeneity - Experiments with flow-reversal.

J Chromatogr A

Department of Analytical and Environmental Chemistry and Szentágothai Research Center, Ifjúság útja 6, H-7624 Pécs, Hungary; MTA-PTE Molecular Interactions in Separation Science Research Group, Ifjúság útja 6, H-7624 Pécs, Hungary; Institute of Bioanalysis, Medical School, University of Pécs, Szigeti út 12, H-7624 Pécs, Hungary. Electronic address:

Published: October 2019

The effect of column end structure and bed heterogeneity of six commercially available reversed-phase chromatographic columns for fast liquid chromatography with different column packing materials - such as fully porous (Waters XBridge C with 1.7 μm particles) and superficially porous (Waters CORTECS C with 1.6 μm particles), with column dimension of 2.1 × 50, 100 or 150 mm were tested with flow-reversal method. The method includes arresting the flow when a non-retained marker (thiourea) has penetrated to a given distance into the column and then reversing the column. Hence, when the flow has been restarted, the sample is eluted at the same end of the column where it entered. The experiments showed that all columns are axially heterogeneous, and some differences could be observed between the two respective column ends. Furthermore, we can conclude that the shorter columns are axially more homogeneous than the longer ones, thus the column length is an influencing factor on the column packing procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2019.05.040DOI Listing

Publication Analysis

Top Keywords

column packing
12
column
11
packing procedure
8
bed heterogeneity
8
porous waters
8
columns axially
8
procedure column
4
column efficiency
4
efficiency bed
4
heterogeneity experiments
4

Similar Publications

Exploring synergistic interactions of ethyl acetate removal and community ecology using magnetite-entrapped biofilters.

Environ Res

January 2025

College of Chemical Engineering, Huaqiao University, Xiamen 361021, China; Xiamen Engineering Research Center of Industrial Wastewater Biochemical Treatment, Xiamen 361021, China; Fujian Provincial Research Center of Industrial Wastewater Biochemical Treatment (Huaqiao University), Xiamen 361021, China. Electronic address:

Emissions of ethyl acetate (EA) exhaust from industrial sources can cause environmental and health risks. EA can be effectively removed by biological filtration with low operating costs and promising good benefits. This study demonstrated the synergistic effect of using magnetite and pebbles as bio-packing in promoting microbial activity and microbial abundance for EA degradation.

View Article and Find Full Text PDF

Retention mechanism in slalom chromatography: Perspectives on the characterization of large DNA and RNA biopolymers in cell and gene therapy.

J Chromatogr A

January 2025

Waters Corporation, Instrument/Core Research/Fundamental, Milford, MA, 01757, USA. Electronic address:

Significant progress has been made in the last two decades in producing small (<2μm), high-purity, and low-adsorption particles, columns and system hardware, for ultra-high pressure liquid chromatography (UHPLC). Simultaneously, the recent rapid expansion of cell and gene therapies for treating diseases necessitates novel analytical technologies for analyzing large (>2 kbp) plasmid double-stranded (ds) DNA (which encodes for the in vitro transcription (IVT) of single-stranded (ss) mRNA therapeutics) and dsRNAs (related to IVT production impurities) biopolymers. In this context, slalom chromatography (SC), a retention mode co-discovered in 1988, is being revitalized using the most advanced column technologies for improved determination of the critical quality attributes (CQAs) of such new therapeutics.

View Article and Find Full Text PDF

Simulation of the performance of pillar array columns using the pore-throat ratio as efficiency descriptor.

J Chromatogr A

January 2025

Institute for Bioengineering, School of Engineering, The University of Edinburgh, Edinburgh, EH9 3BF, United Kingdom.

Traditional packed beds in chromatography suffer from increased band broadening due to the random nature of packing, leading non-ideal fluid flow and channeling. To address these challenges, pillar array columns have been developed, offering improved performance over random packing thanks to their homogenous fluid profiles. The study aims to i) evaluate fluid dynamics and chromatographic performance across different PAC morphologies, ii) establish the influence of column morphology on performance, and iii) assess the correlation between chromatographic performance and hydrodynamic parameters.

View Article and Find Full Text PDF

Packed columns are commonly used in post-combustion processes to capture CO emissions by providing enhanced contact area between a CO-laden gas and CO-absorbing solvent. To study and optimize solvent-based post-combustion carbon capture systems (CCSs), computational fluid dynamics (CFD) can be used to model the liquid-gas countercurrent flow hydrodynamics in these columns and derive key determinants of CO-capture efficiency. However, the large design space of these systems hinders the application of CFD for design optimization due to its high computational cost.

View Article and Find Full Text PDF

The discharge of chromium(VI) into the environment is becoming a significant global concern. Despite the existence of numerous techniques for chromium(VI) removal, substantial challenges persist in effectively mitigating this issue. Therefore, this study investigates the feasibility of using low-cost basalt rock as an adsorbent for chromium(VI) removal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!