[Precise sacroiliac joint screw insertion without computed tomography, digital volume tomography or navigation systems].

Oper Orthop Traumatol

Klinik für Orthopädie und Unfallchirurgie, Mathias-Spital Rheine, Frankenburgstr. 31, 48431, Rheine, Deutschland.

Published: December 2019

Objective: Improvement of sacroiliac positioning of screws by detailed preoperative planning with a DICOM (Digital Imaging and Communications in Medicine-the international standard to store and process medical imaging information) workstation in the absence of advanced technical facilities like intraoperative computer tomography (CT), digital volume tomography (DVT) or a navigation system.

Indications: Mono- or bilateral non- or minor displaced, longitudinal sacral fractures type Denis I and II and pelvic ring fractures (Orthopedic Trauma Association) OTA type B possibly in combination with a ventral procedure.

Contraindications: Displaced sacral fractures type Denis II and III, fractures with central comminution and circulatory unstable patients to be stabilized in the context of emergency care.

Surgical Technique: Preoperative calculation of virtual conventional standard view X‑rays with the CT dataset using common DICOM software (e.g., Siemens via® or Sectra®). Typical landmarks such as screw entry point and end point are projected into the virtual X‑rays. Intraoperative navigation is performed by comparing the virtual standard views with fluoroscopic images of the C‑arm, thereby, simplifying the operative procedure.

Postoperative Management: Postoperative CT scan, pain adapted partial weight bearing and X‑rays of the pelvic ring after 6 and 12 weeks.

Results: Over a 13 month period, an orthopedic surgeon inserted 26 sacroiliac screws in 19 patients utilizing the described method. Postoperative CT scans revealed that all except three screws were precisely positioned without any bone perforation. Of these three screws one had a grade one perforation and two had a grade two perforation according to Smith. No revision was necessary and no neurological deficits were detected. The operating time was on average 33 min and duration of radiation 3.8 min.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00064-019-0607-7DOI Listing

Publication Analysis

Top Keywords

tomography digital
8
digital volume
8
volume tomography
8
sacral fractures
8
fractures type
8
pelvic ring
8
three screws
8
a grade perforation
8
[precise sacroiliac
4
sacroiliac joint
4

Similar Publications

Background: The optimal imaging modality for selecting the device size in patients with atrial fibrillation undergoing one-stop left atrial appendage occlusion (LAAO) with concomitant pulmonary vein isolation (PVi) remains undefined. We compared preprocedural 3-dimensional computed tomography (3D CT) with intra-procedural transesophageal echocardiography (TEE) and left atrial appendage (LAA) angiography in guiding one-stage PVi and LAAO.

Methods: We measured the LAA ostium diameter using an interactive 3D CT system with a central line-based approach and compared these measurements with those from intra-procedural TEE and angiography, and the actual device size.

View Article and Find Full Text PDF

Acute ischemic stroke, a medical emergency caused by reduced cerebral blood flow, results in brain cell damage. While commonly associated with older individuals, strokes can also occur in young and middle-aged adults, posing significant socio-economic and health challenges due to the long-term impact of the condition. This poses significant socio-economic and health challenges because stroke is a leading cause of disability and mortality.

View Article and Find Full Text PDF

Background: Mucosal healing (MH) is the major therapeutic target for Crohn's disease (CD). As the most commonly involved intestinal segment, small bowel (SB) assessment is crucial for CD patients. Yet, it poses a significant challenge due to its limited accessibility through conventional endoscopic methods.

View Article and Find Full Text PDF

Background And Objectives: This study aims to evaluate the correlation between Tumor-Infiltrating Lymphocyte (TIL) levels and Fluorine-18 fluorodeoxyglucose (F-FDG) metabolic parameters, including spleen and bone marrow FDG uptake and tumor heterogeneity in non-luminal breast cancers (NLBC), and to elucidate their association with survival outcomes.

Methods: We retrospectively analyzed data from 100 females with stage 2-4 NLBC who underwent pretreatment F-FDG Positron emission tomography-computed tomography (PET/CT). TIL was scored based on Hematoxylin-Eosin-stained specimens and F-FDG PET metabolic parameters, including maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), metabolic tumor volume (MTV), total lesion glycolysis (TLG), liver, spleen, and bone marrow FDG uptake were calculated.

View Article and Find Full Text PDF

Background: The bolus tracking technique has been used for decades, yet still faces the challenging task of determining the optimal scanning time for individuals. Our study aimed to assess the feasibility of a novel bolus tracking method with a personalized post-trigger delay (PTD) to optimize scanning time and achieve optimized enhancement and contrast homogeneity in aortic computed tomography angiography (CTA).

Methods: Participants undergoing aortic CTA with bolus tracking were prospectively assigned to two different groups: Group A with a fixed 6-second PTD and Group B with a personalized PTD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!