A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A meta-analysis of the effect of stent design on clinical and radiologic outcomes of carotid artery stenting. | LitMetric

Objective: Procedural characteristics, including stent design, may influence the outcome of carotid artery stenting (CAS). A thorough comparison of the effect of stent design on outcome of CAS is thus warranted to allow for optimal evidence-based clinical decision making. This study sought to evaluate the effect of stent design on clinical and radiologic outcomes of CAS.

Methods: A systematic search was conducted in MEDLINE, Embase, and Cochrane databases in May 2018. Included were articles reporting on the occurrence of clinical short- and intermediate-term major adverse events (MAEs; any stroke or death) or radiologic adverse events (new ischemic lesions on postprocedural magnetic resonance diffusion-weighted imaging [MR-DWI], restenosis, or stent fracture) in different stent designs used to treat carotid artery stenosis. Random effects models were used to calculate combined overall effect sizes. Metaregression was performed to identify the effect of specific stents on MAE rates.

Results: From 2654 unique identified articles, two randomized, controlled trials and 66 cohort studies were eligible for analysis (including 46,728 procedures). Short-term clinical MAE rates were similar for patients treated with open cell vs closed cell or hybrid stents. Use of an Acculink stent was associated with a higher risk of short-term MAE compared with a Wallstent (risk ratio [RR], 1.51; P = .03), as was true for use of Precise stent vs Xact stent (RR, 1.55; P < .001). Intermediate-term clinical MAE rates were similar for open vs closed cell stents. Use of open cell stents predisposed to a 25% higher chance (RR, 1.25; P = .03) of developing postprocedural new ischemic lesions on MR-DWI. No differences were observed in the incidence of restenosis, stent fracture, or intraprocedural hemodynamic depression with respect to different stent design.

Conclusions: Stent design is not associated with short- or intermediate-term clinical MAE rates in patients undergoing CAS. Furthermore, the division in open and closed cell stent design might conceal true differences in single stent efficacy. Nevertheless, open cell stenting resulted in a significantly higher number of subclinical postprocedural new ischemic lesions detected on MR-DWI compared with closed cell stenting. An individualized patient data meta-analysis, including future studies with prospective homogenous study design, is required to adequately correct for known risk factors and to provide definite conclusions with respect to carotid stent design for specific subgroups.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2018.11.017DOI Listing

Publication Analysis

Top Keywords

stent design
28
closed cell
16
stent
14
carotid artery
12
ischemic lesions
12
clinical mae
12
mae rates
12
open cell
12
design
8
design clinical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!