Objectives: To determine the validity and inter-session reliability of the Vail Sport Test™.
Design: Cohort study-exploratory methodological research design.
Setting: Clinical Research Laboratory.
Participants: Forty-eight participants who underwent ACL-R.
Main Outcome Measure: Participants performance on the Vail Sport Test™ was graded by an experienced rater in real-time, and simultaneously recorded by a three-dimensional (3D) motion capture system. Construct validity was assessed using the reference standards of the camera system and the IKDC short form. To determine the between-day reliability, a subset of participants returned to repeat the test.
Results: There were no significant difference between the scores collected in real-time and from the kinematic data on the involved limb (p = 0.222). There was a significant difference for the uninvolved limb (p = 0.015). There was no significant difference between the scores collected in real time and those of the IKDC (p = 0.885). Good inter-session reliability (ICC = 0.787) was found for the involved limb.
Conclusion: The results of this study showed good reliability and partially support the validity of the Vail Sport Test as a measure of readiness to return to play.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ptsp.2019.05.001 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!