Assessment of blood flow in the hepatic tumors using non-contrast micro flow imaging: Initial experience.

Clin Hemorheol Microcirc

Department of Ultrasound, Zhongshan Hospital of Fudan University, Shanghai Institute of Medical Imaging, Shanghai, China.

Published: March 2020

Purpose: To evaluate micro-flow imaging (MFI) in depicting the vascular architecture of hepatocellular carcinoma (HCC) and other focal liver lesions.

Materials And Methods: A total of 81 hepatic lesions were enrolled in this study. Each patient underwent CDFI, MFI, and CEUS examinations. The blood flow was first graded into three types (grade 1, 2 and 3) based on its richness with Adeler classification method. The differences in the grade of blood flow in liver tumors were compared between CDFI and MFI. With respect to the presented morphology, the blood flow was further classified into five types (Type I, II, III, IV and V). The morphological differences in blood flow shown by MFI between malignant and benign hepatic tumors were then analyzed.

Results: For the total 81 lesions, MFI detected 61 lesion cases (75.31%) with blood flow grade 2 and 3, which obviously outperformed CDFI which detected 28 cases (34.57%) of grade 2 and 3 (χ2 = 35.27, P = 0.000). The MFI also showed that the most common blood flow morphology of HCC is Type-III (21/48, 43.75%) while the hepatic hemangioma (HEM) is mostly presented as Type V (5/10, 50%). Moreover, the grade of blood flow in MFI varied with different pathological subtypes of HCC (χ2 = 5.610, P = 0.018).

Conclusions: Compared with traditional CDFI, MFI reveals more blood vessels in liver lesions with clearer view of blood flow distribution. Besides, MFI technology can demonstrate grade of blood flow for various differentiation stages of malignant liver tumors.

Download full-text PDF

Source
http://dx.doi.org/10.3233/CH-180532DOI Listing

Publication Analysis

Top Keywords

blood flow
40
cdfi mfi
12
grade blood
12
flow
11
blood
10
mfi
9
hepatic tumors
8
liver tumors
8
flow mfi
8
grade
6

Similar Publications

Impeller radial gap is one of important parts within a blood pump, which may affect the hemodynamics and hemocompatibility. In this study, computational fluid dynamics method was performed to evaluate the impact of radial gap sizes. The volume of scalar shear stress decreased with radial gap sizes increasing.

View Article and Find Full Text PDF

Pediatric Brain Tumors in Western Kenya: Patient Outcomes and Healthcare Providers' Perspectives.

Pediatr Blood Cancer

January 2025

Academic Model Providing Access to Healthcare (AMPATH), Eldoret, Kenya.

Background: Pediatric brain tumors are understudied compared to other pediatric malignancies in low- and middle-income countries. Care delivery is inherently dependent on collaboration between multiple departments. This study aimed to present baseline data of pediatric neuro-oncology care in Western Kenya and illustrate barriers and facilitators of multidisciplinary care.

View Article and Find Full Text PDF

The pleiotropic effects of PCSK9 in cardiovascular diseases beyond cholesterol metabolism.

Acta Physiol (Oxf)

February 2025

Henan Key Laboratory of Medical Tissue Regeneration, Xinxiang Medical University, Xinxiang, China.

Cardiovascular diseases (CVD) are the leading cause of morbidity and mortality globally, with elevated low-density lipoprotein cholesterol (LDL-C) levels being a major risk factor. Proprotein convertase subtilisin/kexin type 9 (PCSK9) plays a critical role in regulating LDL-C levels by promoting the degradation of hepatic low-density lipoprotein receptors (LDLR) responsible for clearing LDL-C from the circulation. PCSK9 inhibitors are novel lipid-modifying agents that have demonstrated remarkable efficacy in reducing plasma LDL-C levels and decreasing the incidence of CVD.

View Article and Find Full Text PDF

Advancement of the Dragon Heart 7-Series for Pediatric Patients With Heart Failure.

Artif Organs

January 2025

BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.

Background: Safe and effective pediatric blood pumps continue to lag far behind those developed for adults. To address this growing unmet clinical need, we are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). Our hybrid TAH design, the Dragon Heart (DH), integrates both an axial flow and centrifugal flow blood pump within a single, compact housing.

View Article and Find Full Text PDF

Acute cardiovascular disorders are incriminated in up to 33% of maternal deaths, and the presence of sickle cell anemia (SCA) aggravates the risk of peripartum complications. Herein, we present a 24-year-old Caribbean woman with known SCA who developed a vaso-occlusive crisis at 36 weeks of gestation that required emergency Cesarean section. In the early postpartum period, she experienced fever with rapid onset of acute respiratory distress in the context of COVID-19 infection that required tracheal intubation and mechanical ventilatory support with broad-spectrum antibiotics and blood exchange transfusion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!