Heart Rate Variability from Wearables: A Comparative Analysis Among Standard ECG, a Smart Shirt and a Wristband.

Stud Health Technol Inform

Dept. of Electronics Information and Bioengineering, Politecnico di Milano, Italy.

Published: September 2019

Heart Rate Variability (HRV) derived from standard one-lead electrocardiography (ECG) was compared with HRV computed by a commercial ECG shirt and with the inter-beat-intervals (IBI) measured by a research-grade photoplethysmographic (PPG) wristband. Signals from 8 subjects were recorded in three experimental phases: during sit; in upright position ("stand"); during controlled respiration. HRV and IBI from both the wearables were computed online (i.e. during the experiment) and stored for subsequent analyses, while the standard ECG was processed offline with state-of-the-art methods to obtain a clean reference HRV. Shirt and wristband signals accuracies were assessed, with respect to the reference HRV, through a between-phase and a beat-to-beat analyses. The former considered several time and frequency domain parameters; the latter was carried out through the Bland-Altman method. Time and frequency domain parameters computed from shirt HRV resulted very similar to the ones extracted from the reference HRV and generally more accurate than the parameters computed from wristband IBI. The Bland-Altman analysis showed that wristband IBI is significantly different from ECG-derived HRV, especially during "stand". Therefore, our results support the idea that some care should be paid in the interpretation of online PPG-derived IBI, while HRV measures online-derived from ECG-shirts seem to be more reliable in the analyzed conditions. The high number of missing beats also suggest that the design of wristband devices should be taken into account to reduce the rate of incorrect measurements, by maximizing sensor adhesion to the skin.

Download full-text PDF

Source

Publication Analysis

Top Keywords

reference hrv
12
hrv
9
heart rate
8
rate variability
8
standard ecg
8
shirt wristband
8
wristband signals
8
time frequency
8
frequency domain
8
domain parameters
8

Similar Publications

Background: Rhinoviruses are known as the leading pathogens of respiratory diseases. Determining the prevalence and phylogeny of rhinoviruses plays a pivotal role in producing vaccines and medications and preventing virus complications. This study investigated the frequency, and genetic variation of rhinoviruses detected in patients referred to Masih Daneshvari Hospital.

View Article and Find Full Text PDF

Introduction  is a complex process influenced by various physiological and psychological factors. Stress, in particular, has been shown to impair wound healing by affecting the immune response and slowing the repair process. Yoga-based relaxation techniques, such as bhramari pranayama and Om chanting, have demonstrated the potential to reduce stress and improve overall well-being.

View Article and Find Full Text PDF

Objective: Aim: To find what extent the state of neurovegetative regulation in children and adolescents with sarcopenia differs from their peers without signs of sarcopenia.

Patients And Methods: Materials and Methods: The sarcopenic index and hand grip strength, which were simultaneously in the range below the 25th percentile of the reference values of these indicators for the corresponding age and gender, were considered the criteria for sarcopenia. A bioelectrical impedance analyzer, "TANITA MC- 780 MA" (Japan), was used to obtain the SI indicator.

View Article and Find Full Text PDF

Cardiovascular autonomic neuropathy in chronic kidney disease: a study of kidney biopsy cases.

BMC Nephrol

December 2024

Division of Nephrology and Hypertension, Department of Internal Medicine, The Jikei University School of Medicine, 3-25-8 Nishi-Shimbashi, Minato-Ku, Tokyo, 105-8461, Japan.

Background: The interplay between cardiac and kidney functions is mediated by the autonomic nervous system. Cardiovascular autonomic neuropathy (CAN) is a well-documented dysfunction of this system, with heart rate variability (HRV) serving as the principal diagnostic tool. CAN is recognized as a prognostic marker for adverse kidney outcomes in diabetic kidney disease (DKD).

View Article and Find Full Text PDF

Autonomic reactivity to mental stress is associated with cardiovascular mortality.

Eur Heart J Open

November 2024

Department of Epidemiology, Rollins School of Public Health, Emory University, 1518 Clifton Rd NE, Atlanta, GA 30322, USA.

Aims: The mechanisms linking acute psychological stress to cardiovascular disease (CVD) mortality are incompletely understood. We studied the relationship of electrocardiographic measures of autonomic dysfunction during acute mental stress provocation and CVD death.

Methods And Results: In a pooled cohort of 765 participants with stable CVD from two related studies, we collected Holter data during standardized laboratory-based mental stress testing with a speech task and followed them for events.