An online beam profiler for laser-accelerated protons.

Rev Sci Instrum

Institut für Laser- und Plasmaphysik, Heinrich-Heine-Universität, 40225 Düsseldorf, Germany.

Published: May 2019

The design and operation of an online energy and spatially resolving detector based on three different scintillators for laser-driven protons are described. The device can be used for a multi-Hertz recording rate. The spatial resolution is <0.5 mm, allowing to retrieve details of the proton beam which is of interest, e.g., for radiographic applications. At the same time, the particle energy is divided into three energy bands between 1 MeV and 5 MeV to retrieve the proton energy spectrum. The absolute response of the detector was calibrated at a conventional proton accelerator.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5086248DOI Listing

Publication Analysis

Top Keywords

online beam
4
beam profiler
4
profiler laser-accelerated
4
laser-accelerated protons
4
protons design
4
design operation
4
operation online
4
online energy
4
energy spatially
4
spatially resolving
4

Similar Publications

Validation of a Monte Carlo-based dose calculation engine including the 1.5 T magnetic field for independent dose-check in MRgRT.

Phys Med

January 2025

Department of Radiation Oncology, IRCCS Sacro Cuore Don Calabria Hospital, Via Don A. Sempreboni 5, 37024 Negrar di Valpolicella, VR, Italy; University of Brescia, Brescia, Italy.

Purpose: Adaptive MRgRT by 1.5 T MR-linac requires independent verification of the plan-of-the-day by the primary TPS (Monaco) (M). Here we validated a Monte Carlo-based dose-check including the magnetostatic field, SciMoCa (S).

View Article and Find Full Text PDF

Purpose: Daily online adaptive radiation therapy (oART) opens the opportunity to treat gastric mucosa-associated lymphoid tissue (MALT) lymphoma with a reduced margin. This study reports our early experience of cone beam computed tomography (CBCT)-based daily oART treating gastric MALT lymphoma with breath-hold and reduced margins.

Methods And Materials: Ten patients were treated on a CBCT-based oART system.

View Article and Find Full Text PDF

Background And Purpose: A novel ring-gantry cone-beam computed tomography (CBCT) imaging system shows improved image quality compared to its conventional version, but its effect on autosegmentation is unknown. This study evaluates the impact of this high-performance CBCT on autosegmentation performance, inter-observer variability, contour correction times and delineation confidence, compared to the conventional CBCT.

Materials And Methods: Twenty prostate cancer patients were enrolled in this prospective clinical study.

View Article and Find Full Text PDF

Purpose: To use imaging data from stereotactic MR-guided online adaptive radiotherapy (SMART) of ultracentral lung tumors (ULT) for development of a safe non-adaptive approach towards stereotactic body radiotherapy (SBRT) of ULT.

Patients And Methods: Analysis is based on 19 patients with ULT who received SMART (10 × 5.0-5.

View Article and Find Full Text PDF

CT-guided adaptive radiotherapy (ART) for the treatment of pancreatic adenocarcinoma is rapidly increasing and has been shown to provide advanced treatment tools comparable to magnetic resonance imaging (MRI)-guided adaptive therapy. Here, we provide the first case report of a local pancreatic recurrence treatment after definitive resection using cone beam computed tomography (CBCT)-guided ART (CT-guided ART) enabled by HyperSight imaging (Varian Medical Systems, Inc., Palo Alto, CA, USA) for daily delineation of organs-at-risk (OARs) and target to improve the quality of online ART.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!