Matrix-matched standards in the liquid chromatography-mass spectrometry determination of neonicotinoids in soil and sediment.

J Chromatogr A

Department of Environmental Toxicology, Texas Tech University, PO Box 41163, Lubbock, TX 79409, United States. Electronic address:

Published: September 2019

The use of matrix-matched standards with a solid-liquid extraction and salting out without the addition of further cleanup steps or costly cleanup procedures associated with the quick, easy, cheap, effective, robust, and safe (QuEChERS) method was evaluated to address variations in ionization efficiency in the LC-MS/MS determination of neonicotinoid pesticides in complex environmental samples. Limits of detection (1.4-3.4 ng/g) and limits of quantitation (4.6-11.3 ng/g) for various neonicotinoid analogs were comparable to previously reported QuEChERS extraction methods. Mean recovery of standard neonicotinoid samples spiked with 10 ng/g was found to be 78.0-100.5%, while samples spiked with 100 ng/g were found to be 55.1-99.9%. Recovery of analytes was matrix dependent; the highest recovery was from sediment (86.2-100.5%) followed by laboratory sand (70.9-81.7%) and agricultural soil (55.5-102.6%), respectively. Optimization of this methodology resulted in the reduction of procedure time and cost, and can aid in environmental monitoring efforts of common neonicotinoid pesticides in soils and sediments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2019.05.035DOI Listing

Publication Analysis

Top Keywords

matrix-matched standards
8
neonicotinoid pesticides
8
samples spiked
8
standards liquid
4
liquid chromatography-mass
4
chromatography-mass spectrometry
4
spectrometry determination
4
determination neonicotinoids
4
neonicotinoids soil
4
soil sediment
4

Similar Publications

Development and validation of an UPLC-MS/MS method with polarity switching for simultaneous determination of 14 antiepileptic drugs and 2 metabolites in human serum.

J Pharm Biomed Anal

January 2025

Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, Xuzhou Medical University, Xuzhou 221004, China; Department of Pharmacy, Suining People's Hospital Affiliated to Xuzhou Medical University, Suining 221202, China; Department of Pharmaceutical Analysis, Xuzhou Medical University, Xuzhou 221204, China. Electronic address:

Currently, treatment with antiepileptic drugs (AEDs) is still the first choice for epileptic patients, while monitoring their blood concentrations is undoubtedly beneficial for minimizing their adverse side effects and optimizing their therapeutic effects. In this study, an ultra-high performance liquid chromatography coupled with tandem mass spectrometry with polarity switching was developed and validated for simultaneous determination of 14 AEDs and 2 active metabolites in human serum. Olanzapine was selected as the internal standard.

View Article and Find Full Text PDF

Determination and validation of polycyclic aromatic hydrocarbons (PAH4) in katsuobushi, plant-based food supplements, and cocoa bean shells using GC-MS/MS.

J Food Drug Anal

December 2024

Division of Research and Analysis, Taiwan Food and Drug Administration, Ministry of Health and Welfare, No.161-2, Kunyang St, Nangang District, Taipei City 11561, Taiwan, R.O.C.

Polycyclic aromatic hydrocarbons (PAHs) are primarily generated through the incomplete combustion or pyrolysis of organic materials in various industrial processes. Foods may become contaminated with environmental PAHs found in air, soil, or water, or through industrial food processing methods such as smoking, roasting, drying, and grilling. The Ministry of Health and Welfare in Taiwan has established maximum levels for benzo[a]pyrene (BaP) and indicative values for BaP as well as PAH4 (the sum of benz[a]anthracene, chrysene, benzo[b]fluoranthene, and benzo[a]pyrene) in foods as operational guidelines.

View Article and Find Full Text PDF
Article Synopsis
  • The study developed a portable mass spectrometry technique for accurately measuring tirofiban drug concentrations in blood to enhance patient safety and treatment efficacy.
  • The method identified a significant parent ion peak for tirofiban and optimized various parameters, achieving a limit of detection (LOD) and limit of quantification (LOQ) of 10.1 and 33.7 μg·L, respectively.
  • Although the technique faced some challenges from blood sample matrix effects, it successfully detected tirofiban in 10 out of 12 clinical samples, demonstrating the need for further optimization and validation to boost sensitivity and stability.
View Article and Find Full Text PDF

Recently, an instrumental analysis using LC-MS/MS has been developed and validated for paralytic shellfish toxins (PSTs) and tetrodotoxin (TTX) in bivalve molluscs in Japanese domestic and overseas. The method for 11 PSTs and TTX in scallops was validated in accordance with a previous report and CODEX-STAN. The samples were prepared by adding the standard mixture of PSTs and TTX to scallop (Patinopecten yessoensis) homogenates, extracted with 1% acetic acid and then cleaned up using an ENVI-Carb (250 mg/3 mL) cartridge.

View Article and Find Full Text PDF

Preparation of REE-doped CaF single crystals for accurate determination of REE concentrations in CaF crystals via UV-LA-ICP-MS.

Talanta

December 2024

Key Laboratory of Testing and Tracing of Rare Earth Products, State Administration for Market Regulation, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, 341000, PR China; Jiangxi Provincial Key Laboratory of Functional Molecular Materials Chemistry, School of Chemistry and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou, 341000, PR China. Electronic address:

Accurate determination of rare earth element (REE) concentrations in CaF crystals using UV-LA-ICP-MS is important but challenging due to the lack of matrix-matched reference materials. In this study, a REE-doped CaF single crystal (CaF-05), prepared via the Bridgman-Stockbarger technique, was systematically characterized to assess its optical properties, homogeneity, and stability. Analyses using portable laser irradiation, UV-vis spectroscopy, back scatter electron (BSE) imaging, and cathodoluminescence (CL) demonstrated that the crystal possesses high optical quality and exhibits distinct optical adsorption properties compared to the silicate reference material NIST SRM 610.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!