Rationale: A Mason type III radial head fracture, which is characterized by comminuted fragments of the radial head, is a severe injury. Open reduction and internal fixation (ORIF) is an alternative treatment method; however, the technique of using an on-table reduction in combination with surgical glue is rarely reported.

Patient Concerns: A 48-year-old man was admitted to our department with complaints of elbow pain after falling down. Elbow radiography and computed tomography (CT) demonstrated characteristics of fractures before the operation.

Diagnosis: Radiographic images showed a Mason type III radial head fracture.

Interventions: The patient underwent ORIF at our hospital. During the operation, the technique of on-table reconstruction combined with surgical glue was used.

Outcomes: The patient recovered well and was able to participate in his usual work.

Lessons: Mason type III radial head fractures could be treated with ORIF, and a satisfactory result could be anticipated, thus avoiding a radial head replacement or resection. Anatomical reduction of a comminuted radial head could be obtained via an on-table reconstruction and application of surgical glue.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6709144PMC
http://dx.doi.org/10.1097/MD.0000000000015863DOI Listing

Publication Analysis

Top Keywords

radial head
28
surgical glue
16
mason type
16
type iii
16
iii radial
16
head fractures
8
technique on-table
8
on-table reconstruction
8
radial
7
head
7

Similar Publications

To develop and validate non-contrast computed tomography (NCCT)-based radiomics method combines machine learning (ML) to investigate invisible microscopic acute ischaemic stroke (AIS) lesions. We retrospectively analyzed 1122 patients from August 2015 to July 2022, whose were later confirmed AIS by diffusion-weighted imaging (DWI). However, receiving a negative result was reported by radiologists according to the NCCT images.

View Article and Find Full Text PDF

Background And Objectives: A typical workflow for deep brain stimulation (DBS) surgery consists of head frame placement, followed by stereotactic computed tomography (CT) or MRI before surgical implantation of the hardware. At some institutions, this workflow is prolonged when the imaging scanner is located far away from the operating room, thereby increasing workflow times by the addition of transport times. Recently, the intraoperative O-arm has been shown to provide accurate image fusion with preoperative CT or MR imaging, suggesting the possibility of obtaining an intraoperative localization scan and postoperative confirmation.

View Article and Find Full Text PDF

Objective: To evaluate the effects of Fanconi anemia (FA) on retinal and choroidal microvasculature using Optical Coherence Tomography (OCT) and Optical Coherence Tomography Angiography (OCTA).

Design: Cohort study with age-matched controls.

Subjects And Participants: This study included 11 eyes from 11 patients diagnosed with FA and 12 eyes from 12 age-matched healthy controls.

View Article and Find Full Text PDF

Purpose: T1-weighted signal intensity ratios (SIR) comparing pancreas to spleen (SIRps) or muscle (SIRpm) can semiquantitatively assess T1 signal change associated with pancreatitis. However, there is no standardized methodology for generating these ratios. We set out to determine the impact of MRI sequence as well as region of interest (ROI) location, shape, and size on T1 SIR.

View Article and Find Full Text PDF

Aneurysms of the middle cerebral artery (MCA) account for up to 40% of all unruptured intracranial aneurysms [1-3] and 14% to 20% of ruptured ones. [4-5] Giant MCA aneurysms are rare, representing 10% of cases [6], but carry an aggressive natural history, with the UCAS Japan study reporting an annual rupture rate of ∼ 17%. [7].

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!