Background: The long-term results of endocardial and percutaneous epicardial catheter ablation of ventricular tachycardia (VT) in patients with structural heart disease are disappointing. Arrhythmia recurrence after ablation and VTs with an epicardial substrate remain a clinical challenge. The purpose of this manuscript is to elaborate on feasibility and potential advantages of a surgical hybrid ablation (i.e., combined endocardial and surgical epicardial ablation) based on our initial experience consisting of five cases.

Methods: Endocardial electro-anatomical voltage and activation maps were created (Carto, Biosense Webster, California, USA), and endocardial radiofrequency (RF) applications were applied at exit sites, low voltage areas and isthmi. Next, after surgical access, epicardial voltage and activation maps were produced in combination with visual assessment of the epicardial substrate. Epicardial low voltage areas, isthmi and exit sites were identified and ablated using RF energy.

Results: After the procedure, VT was non-inducible in 80% of the cases (4/5, in one case no induction was performed). No peri-procedural complications occurred. After a mean follow-up of 18 months, one patient remained in sinus rhythm without, and 2 with use of antiarrhythmic drugs. One patient needed a redo procedure after 21 months, and in one patient the amiodarone dose was raised because of 2 sustained VTs. After this additional treatment, both kept sinus rhythm.

Conclusions: Hybrid VT ablation is a safe and effective patient tailored procedure that comprises the major advantage of combining direct anatomical visualization and enhanced catheter stability with high-density 3D mapping. As a consequence, this procedure should be considered as a valid treatment option in complex VT management.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6533820PMC
http://dx.doi.org/10.4022/jafib.2118DOI Listing

Publication Analysis

Top Keywords

hybrid ablation
12
ablation ventricular
8
ventricular tachycardia
8
epicardial substrate
8
voltage activation
8
activation maps
8
exit sites
8
low voltage
8
voltage areas
8
areas isthmi
8

Similar Publications

Purpose: In magnetic resonance-guided focused ultrasound (MRgFUS) breast therapies, the focal location must be characterized to guide successful treatment. Focal characterization is difficult because heterogeneous breast tissues introduce phase aberrations that blur and shift the focus and traditional guidance methods do not work in adipose tissues. The purpose of this work is to evaluate numerical simulations of MRgFUS that predict the focal location.

View Article and Find Full Text PDF

We report a case of a patient with dilated cardiomyopathy who experienced recurrent ventricular tachycardia (VT) and multiple defibrillations following CRT-D implantation. Due to worsening cardiac function, the patient required surgical implantation of a left ventricular assist device (LVAD) as a bridge to heart transplantation. During the procedure, we used the Ensite three-dimensional mapping system to perform activation and substrate mapping of the VT targets, followed by endocardial and epicardial cryoballoon ablation of clinical VT.

View Article and Find Full Text PDF

Background: Intraoperative imaging is critical for achieving precise cancer resection. Among available techniques, Raman spectral imaging emerges as a promising modality due to its high spatial resolution and signal stability. However, its clinical application for in vivo imaging is limited by the inherently weak Raman scattering signal.

View Article and Find Full Text PDF

DECT sparse reconstruction based on hybrid spectrum data generative diffusion model.

Comput Methods Programs Biomed

January 2025

Key Laboratory of Computer Network and Information Integration (Southeast University), Ministry of Education, Nanjing, China; School of Computer Science and Engineering, Southeast University, Nanjing, China.

Purpose: Dual-energy computed tomography (DECT) enables the differentiation of different materials. Additionally, DECT images consist of multiple scans of the same sample, revealing information similarity within the energy domain. To leverage this information similarity and address safety concerns related to excessive radiation exposure in DECT imaging, sparse view DECT imaging is proposed as a solution.

View Article and Find Full Text PDF

Predicting cobalt ion concentration in hydrometallurgy zinc process using data decomposition and machine learning.

Sci Total Environ

January 2025

State Key Laboratory of Complex Nonferrous Metal Resources Clean Utilization, Kunming University of Science and Technology, Kunming, Yunnan 650093, PR China; Faculty of Metallurgical and Energy Engineering, Kunming University of Science and Technology, Kunming, Yunnan 650093, PR China. Electronic address:

Solid waste is one of the primary contributors to environmental pollution currently, it is crucial to enhance the prevention and control of solid waste pollution in environmental management. The effectiveness of the second stage of purification in the industrial zinc hydrometallurgy is determined by the concentration of cobalt ion. Manual testing and monitoring of cobalt ion concentration are time consuming and costly, and prone to delays, which can result in discharge of cobalt ion concentration that does not meet the standards, leading to water pollution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!