Background: Interferon gamma release assays (IGRAs) are blood tests recommended for the diagnosis of tuberculosis (TB) infection. There is currently uncertainty about the role and clinical utility of IGRAs in the diagnostic workup of suspected active TB in routine NHS clinical practice.

Objectives: To compare the diagnostic accuracy and cost-effectiveness of T-SPOT. (Oxford Immunotec, Abingdon, UK) and QuantiFERON TB GOLD In-Tube (Cellestis, Carnegie, VIC, Australia) for diagnosis of suspected active TB and to estimate the diagnostic accuracy of second-generation IGRAs.

Design: Prospective within-patient comparative diagnostic accuracy study.

Setting: Secondary care.

Participants: Adults (aged ≥ 16 years) presenting as inpatients or outpatients at 12 NHS hospital trusts in London, Slough, Oxford, Leicester and Birmingham with suspected active TB.

Interventions: The index tests [T-SPOT. and QuantiFERON GOLD In-Tube (QFT-GIT)] and new enzyme-linked immunospot assays utilising novel antigens (Rv3615c, Rv2654, Rv3879c and Rv3873) were verified against a composite reference standard applied by a panel of clinical experts blinded to IGRA results.

Main Outcome Measures: Sensitivity, specificity, predictive values and likelihood ratios were calculated to determine diagnostic accuracy. A decision tree model was developed to calculate the incremental costs and incremental health utilities [quality-adjusted life-years (QALYs)] of changing from current practice to using an IGRA as an initial rule-out test.

Results: A total of 363 patients had active TB (culture-confirmed and highly probable TB cases), 439 had no active TB and 43 had an indeterminate final diagnosis. Comparing T-SPOT. and QFT-GIT, the sensitivities [95% confidence interval (CI)] were 82.3% (95% CI 77.7% to 85.9%) and 67.3% (95% CI 62.1% to 72.2%), respectively, whereas specificities were 82.6% (95% CI 78.6% to 86.1%) and 80.4% (95% CI 76.1% to 84.1%), respectively. T-SPOT. was more sensitive than QFT-GIT (relative sensitivity 1.22, 95% CI 1.14 to 1.31;  < 0.001), but the specificities were similar (relative specificity 1.02, 95% CI 0.97 to 1.08;  = 0.3). For both IGRAs the sensitivity was lower and the specificity was higher for human immunodeficiency virus (HIV)-positive than for HIV-negative patients. The most promising novel antigen was Rv3615c. The added value of Rv3615c to T-SPOT. was a 9% (95% CI 5% to 12%) relative increase in sensitivity at the expense of specificity, which had a relative decrease of 7% (95% CI 4% to 10%). The use of current IGRA tests for ruling out active TB is unlikely to be considered cost-effective if a QALY was valued at £20,000 or £30,000. For T-SPOT., the probability of being cost-effective for a willingness to pay of £20,000/QALY was 26% and 21%, when patients with indeterminate test results were excluded or included, respectively. In comparison, the QFT-GIT probabilities were 8% and 6%. Although the use of IGRAs is cost saving, the health detriment is large owing to delay in diagnosing active TB, leading to prolonged illness. There was substantial between-patient variation in the tests used in the diagnostic pathway.

Limitations: The recruitment target for the HIV co-infected population was not achieved.

Conclusions: Although T-SPOT. was more sensitive than QFT-GIT for the diagnosis of active TB, the tests are insufficiently sensitive for ruling out active TB in routine clinical practice in the UK. Novel assays offer some promise.

Future Work: The novel assays require evaluation in distinct clinical settings and in immunosuppressed patient groups.

Funding: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and the NIHR Health Protection Research Unit in Respiratory Infections, Imperial College London, London, UK.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6556820PMC
http://dx.doi.org/10.3310/hta23230DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
16
suspected active
12
interferon gamma
8
gamma release
8
release assays
8
quantiferon gold
8
gold in-tube
8
diagnostic
6
active
6
accuracy
5

Similar Publications

Background: Acute respiratory distress syndrome (ARDS) is a serious threat to human life. Hence, early and accurate diagnosis and treatment are crucial for patient survival. This meta-analysis evaluates the accuracy of artificial intelligence in the early diagnosis of ARDS and provides guidance for future research and applications.

View Article and Find Full Text PDF

Virtual biopsy for non-invasive identification of follicular lymphoma histologic transformation using radiomics-based imaging biomarker from PET/CT.

BMC Med

January 2025

Department of Nuclear Medicine, West China Hospital, Sichuan University, Guoxue Alley, Address: No.37, Chengdu City, Sichuan, 610041, China.

Background: This study aimed to construct a radiomics-based imaging biomarker for the non-invasive identification of transformed follicular lymphoma (t-FL) using PET/CT images.

Methods: A total of 784 follicular lymphoma (FL), diffuse large B-cell lymphoma, and t-FL patients from 5 independent medical centers were included. The unsupervised EMFusion method was applied to fuse PET and CT images.

View Article and Find Full Text PDF

Objectives: Over 30% of people worldwide suffer from metabolic dysfunction-associated steatotic liver disease (MASLD), a significant global health issue. Identifying and preventing high-risk individuals for MASLD early is crucial. The purpose of our study is to investigate the factors related to the development of MASLD and develop a risk prediction model for its occurrence.

View Article and Find Full Text PDF

This study aimed to evaluate the usefulness of amplicon-based real-time metagenomic sequencing applied to cerebrospinal fluid (CSF) for identifying the causative agents of bacterial meningitis. We conducted a 16S rRNA amplicon sequencing using a nanopore-based platform, alongside routine polymerase chain reaction (PCR) testing or bacterial culture, to compare its clinical performance in pathogen detection on CSF samples. Among 17 patients, nanopore-based sequencing, multiplex PCR, and bacterial culture detected potential bacterial pathogens in 47.

View Article and Find Full Text PDF

Value of multi-parameter I-MIBG scintigraphy in the differential diagnosis of Parkinson's disease.

EJNMMI Res

January 2025

Department of Nuclear Medicine, Beijing Friendship Hospital, Capital Medical University, 95 Yong'an Road, Xicheng District, Beijing, China.

Background: I-MIBG scintigraphy plays a significant role in diagnosing Parkinson's disease (PD), with most studies primarily targeting cardiac uptake and relying on traditional ratio-based parameters for assessment. However, due to variations in scanning conditions and image processing methodologies, the clinical utility of different parameters remains a subject of debate. This study aims to evaluate the diagnostic accuracy of multi-parameter I-3-Iodobenzylguanidine (MIBG) scintigraphy and to identify the most reliable metrics for distinguishing PD from Parkinson-plus syndromes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!