Outcome of expandable endoprosthesis: A single centre retrospective review.

J Orthop Surg (Hong Kong)

Department of Orthopaedic Surgery, Faculty of Medicine, National Orthopaedic Centre of Excellence in Research and Learning, University of Malaya, Kuala Lumpur, Malaysia.

Published: March 2020

Purpose: Expandable endoprosthesis allows limb salvage in children with an option to leading a better life. However, the revision rate and implant-related complications impose as a limitation in the skeletal immature. This study investigates the functional outcomes and complications related to expandable endoprosthesis in our centre.

Materials And Methods: Twenty surviving patients with expandable endoprosthesis from 2006 till 2015 were scored using Musculoskeletal Tumour Society (MSTS) outcomes instrument and reviewed retrospectively for range of motion of respected joints, limb length discrepancy, number of surgeries performed, complications and oncological outcomes. Patients with less than 2 years of follow-up were excluded from this study.

Results: Forty-five percentage patients reached skeletal maturity with initial growing endoprosthesis and 25% of patients were revised to adult modular prosthesis. One hundred fifty-seven surgeries were performed over the 9-year period. The average MSTS score was 90.83%. The mortality rate was 10% within 5 years due to advanced disease. Infection and implant failure rate was 15% each. The event-free survival was 50% and overall survival rate was 90%.

Conclusion: There is no single best option for reconstruction in skeletally immature. This study demonstrates a favourable functional and survival outcome of paediatric patients with expandable endoprosthesis. The excellent MSTS functional scores reflect that patients were satisfied and adjusted well to activities of daily living following surgery despite the complications.

Download full-text PDF

Source
http://dx.doi.org/10.1177/2309499019850313DOI Listing

Publication Analysis

Top Keywords

expandable endoprosthesis
20
immature study
8
patients expandable
8
surgeries performed
8
endoprosthesis
6
patients
6
outcome expandable
4
endoprosthesis single
4
single centre
4
centre retrospective
4

Similar Publications

Surgical Bailout in Patients Undergoing Transfemoral Transcatheter Aortic Valve Replacement: Incidence, Trends, and Clinical Outcomes.

JACC Cardiovasc Interv

January 2025

Department of Cardiology, Amsterdam University Medical Center, University of Amsterdam, Amsterdam Cardiovascular Sciences, Amsterdam, the Netherlands. Electronic address:

Background: Transcatheter aortic valve replacement (TAVR) harbors the risk of periprocedural complications that require emergent cardiac surgery, or "surgical bailout." Surgical bailout intends to be lifesaving but is associated with high mortality. This has given rise to discussion on the necessity of surgical backup during TAVR.

View Article and Find Full Text PDF

Initial Multicenter Experience With a Novel Self-Expanding TAVR System in Patients With Aortic Valve Stenosis.

JACC Cardiovasc Interv

January 2025

Clinic for General and Interventional Cardiology/Angiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany. Electronic address:

Background: As transcatheter aortic valve replacement is performed increasingly in younger, low-risk patients, the need for commissural alignment and coronary access has increased. Design elements of the JenaValve Trilogy (JVT) transcatheter heart valve (THV) ensure both.

Objectives: This study sought to evaluate the outcome of patients with aortic stenosis (AS) treated with this novel transfemoral, self-expanding THV.

View Article and Find Full Text PDF

Insights on the role of cryoprotectants in enhancing the properties of bioinks required for cryobioprinting of biological constructs.

J Mater Sci Mater Med

January 2025

Tissue Engineering & Additive Manufacturing (TEAM) Lab, Centre for Nanotechnology & Advanced Biomaterials (CeNTAB), ABCDE Innovation Centre, School of Chemical & Biotechnology (SCBT), SASTRA Deemed University, Thanjavur, 613401, India.

Preservation and long-term storage of readily available cell-laden tissue-engineered products are major challenges in expanding their applications in healthcare. In recent years, there has been increasing interest in the development of off-the-shelf tissue-engineered products using the cryobioprinting approach. Here, bioinks are incorporated with cryoprotective agents (CPAs) to allow the fabrication of cryopreservable tissue constructs.

View Article and Find Full Text PDF

Severe mitral regurgitation (MR) following surgical repair of the mitral valve poses a significant clinical challenge. Patients who have undergone surgery are typically at high risk for a second operation. This report details the case of a 54-year-old male who underwent aortic valve replacement and mitral valve repair using a 34-ring, 14 years prior.

View Article and Find Full Text PDF

Highly Responsive Robotic Prosthetic Hand Control Considering Electrodynamic Delay.

Sensors (Basel)

December 2024

Department of Robotics and Mechatronics, Tokyo Denki University, Tokyo 120-8551, Japan.

As robots become increasingly integrated into human society, the importance of human-machine interfaces continues to grow. This study proposes a faster and more accurate control system for myoelectric prostheses by considering the Electromechanical Delay (EMD), a key characteristic of Electromyography (EMG) signals. Previous studies have focused on systems designed for wrist movements without attempting implementation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!