Inpatient diabetes management of those on hemodialysis poses a major challenge. In a post hoc analysis of a randomized controlled clinical trial, we compared the efficacy of fully automated closed-loop insulin delivery vs. usual care in patients undergoing hemodialysis while in hospital. Compared to control patients receiving conventional subcutaneous insulin therapy, those patients receiving closed-loop insulin delivery significantly increased the proportion of time when a continuous glucose monitor was in the target range of 5.6-10.0 mmol/l by 37.6 percent without increasing the risk of hypoglycemia. Thus, closed-loop insulin delivery offers a novel way to achieve effective and safe glucose control in this vulnerable patient population.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.kint.2019.03.006DOI Listing

Publication Analysis

Top Keywords

closed-loop insulin
16
insulin delivery
16
patients receiving
8
insulin
5
fully closed-loop
4
delivery
4
delivery improves
4
improves glucose control
4
glucose control inpatients
4
inpatients type
4

Similar Publications

Unlabelled: The hybrid closed-loop (HCL) system, Medtronic MiniMed 770G, has been available for use by Japanese individuals with type 1 diabetes mellitus since 2021. The aim of this study was to evaluate the effect of its use on glycemic variability and quality of life (QOL) in this population. This multicenter, open-label, prospective observational study included 14 Japanese individuals with type 1 diabetes mellitus treated with MiniMed 640G.

View Article and Find Full Text PDF

Patients with type 1 diabetes and their physicians have long desired a fully closed-loop artificial pancreas (AP) system that can alleviate the burden of blood glucose regulation. Although deep reinforcement learning (DRL) methods theoretically enable adaptive insulin dosing control, they face numerous challenges, including safety and training efficiency, which have hindered their clinical application. This paper proposes a safe and efficient adaptive insulin delivery controller based on DRL.

View Article and Find Full Text PDF

This study evaluated a next-generation automated insulin delivery (AID) algorithm for Omnipod in type 1 and type 2 diabetes across multiple phases: 14-day run-in with usual therapy, 48-h AID use in a hotel setting (type 1 only), and up to 6 weeks of outpatient AID use. Participants did, or did not, deliver manual boluses at alternating periods. Twelve adults with type 1 diabetes completed the hotel phase; 9 of those 12 plus 8 adults with type 2 diabetes completed the subsequent outpatient phase.

View Article and Find Full Text PDF

To evaluate real-world outcomes in adults with type 1 diabetes initiating open-source automated insulin delivery systems (OS-AID). Adults with type 1 diabetes who commenced OS-AID, between May 2016 and April 2021, across 12 centers in the United Kingdom were included. Anonymized clinical data, collected during routine clinical care between December 2019 and November 2023, were submitted to a secure web-based tool within the National Health Service network.

View Article and Find Full Text PDF

Objectives: Type 1 diabetes (T1D) in pregnancy is challenging. This study explores how assisted hybrid closed-loop (HCL) therapy versus sensor-augmented pump therapy (SAPT) impacts quality of life (QoL) in pregnancy.

Methods: We interviewed 22 of 24 participants randomized to HCL therapy or SAPT in the Pregnancy Intervention with a Closed-Loop System study.

View Article and Find Full Text PDF