Acute and chronic toxicity of nickel to nitrifiers at different temperatures.

J Environ Sci (China)

Department of Civil and Environmental Engineering, University of Western Ontario, London, Ontario N6A 5B9, Canada; Department of Chemical and Biochemical Engineering, University of Western Ontario, London, Ontario N6A 5B9, Canada. Electronic address:

Published: August 2019

This study investigated the acute nickel toxicity on nitrification of low ammonia synthetic wastewater at 10, 23, and 35°C. The nickel inhibition half-velocity constants (K) for ammonia oxidizing bacteria (AOB) and nitrite oxidizing bacteria (NOB) based on Ni/MLSS ratio at 10, 23, and 35°C were 5.4 and 5.6 mg Ni/g MLSS, 4.6 and 3.5 mg Ni/g MLSS, and 9.1 and 2.7 mg Ni/g MLSS, respectively. In addition, chronic toxicity of nickel to nitrification of low ammonia synthetic wastewater was investigated at 10°C in two sequencing batch reactors (SBRs). Long-term SBRs operation and short-term batch tests were comparable with respect to the extent of inhibition and corresponding Ni/MLSS ratio. The μ, b, and K of AOB were 0.16 day, 0.098 day and 2.08 mg O/L after long-term acclimatization to nickel of 1 mg/L at 10°C, high dissolved oxygen (DO) (7 mg/L) and long solids retention time (SRT) of 63-70 days. Acute nickel toxicity of nitrifying bacteria was completely reversible.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jes.2019.03.009DOI Listing

Publication Analysis

Top Keywords

ni/g mlss
12
chronic toxicity
8
toxicity nickel
8
acute nickel
8
nickel toxicity
8
nitrification low
8
low ammonia
8
ammonia synthetic
8
synthetic wastewater
8
oxidizing bacteria
8

Similar Publications

Acute and chronic toxicity of nickel to nitrifiers at different temperatures.

J Environ Sci (China)

August 2019

Department of Civil and Environmental Engineering, University of Western Ontario, London, Ontario N6A 5B9, Canada; Department of Chemical and Biochemical Engineering, University of Western Ontario, London, Ontario N6A 5B9, Canada. Electronic address:

This study investigated the acute nickel toxicity on nitrification of low ammonia synthetic wastewater at 10, 23, and 35°C. The nickel inhibition half-velocity constants (K) for ammonia oxidizing bacteria (AOB) and nitrite oxidizing bacteria (NOB) based on Ni/MLSS ratio at 10, 23, and 35°C were 5.4 and 5.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!