A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of cryoballoon-guided pulmonary vein isolation on non-invasive autonomic tests in patients with paroxysmal atrial fibrillation. | LitMetric

Background: Pulmonary vein isolation (PVI) modulates the intrinsic cardiac autonomic nervous system (ANS). We evaluated the impact of PVI on 5 non-invasive autonomic tests.

Methods: Thirty patients (76% male, mean age 60.37 ± 9.02 years) with paroxysmal atrial fibrillation (AF) underwent cryoballoon-guided PVI. Five autonomic tests were performed 24hrs before and after PVI (N = 30) and repeated after 6months (N = 22). Parasympathetic function was measured by heart rate (HR) variability during deep breathing (E/I ratio, I-E difference), Valsalva maneuver (Valsalva-ratio) and head-up tilt test (30/15 ratio). Sympathetic function was measured by systolic BP response to sustained handgrip and 10' tilting and by diastolic BP response to cold water.

Results: 24hrs after PVI, baseline HR increased from 57.93 ± 9.06 bpm to 71.10 ± 12.75 bpm (p < 0.001). At 6 months, baseline HR was lower than immediately post-PVI (62.59 ± 7.89 vs 71.36 ± 13.58 bpm, p = 0.032) but still higher in comparison to pre-PVI (62.59 ± 7.89 vs 57.09 ± 8.80 bpm, p < 0.001). No differences were seen in baseline BP and parasympathetic tests acutely and at 6months. Besides an acute lowering in systolic BP increase during handgrip test, all sympathetic tests remained unchanged.

Conclusions: An acute HR increase attenuated at 6months and an acute lowered systolic BP response to sustained handgrip were the only changes after cryoballoon-guided PVI. Non-invasive autonomic tests seem therefore not appropriate to evaluate the autonomic modulatory effect of PVI, either due to a too limited sensitivity or a too localized effect of PVI to influence test results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6823709PMC
http://dx.doi.org/10.1016/j.ipej.2019.05.002DOI Listing

Publication Analysis

Top Keywords

pulmonary vein
8
vein isolation
8
non-invasive autonomic
8
autonomic tests
8
paroxysmal atrial
8
atrial fibrillation
8
24hrs pvi
8
function measured
8
pvi
5
impact cryoballoon-guided
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!