A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Tissue distribution study of mangiferin after intragastric administration of mangiferin monomer, Rhizoma Anemarrhenae, and Rhizoma Anemarrhenae-Phellodendron decoctions in normal or type 2 diabetic rats by LC-MS/MS. | LitMetric

A simple, accurate, and reliable liquid chromatography-mass spectrometry (LC-MS/MS) method was developed and validated for the determination of mangiferin in rat plasma and tissue homogenates using rutin as an internal standard (IS). Chromatographic separation was achieved on a Shiseido CAPCELL PAK C column (150 × 2.0 mm, 5 μm) using a gradient elution of 1% acetic acid in water and methanol at a flow rate of 300 μL·min. Quantification was performed on an API 4000 triple-quadrupole mass spectrometer equipped with a turbo electrospray ionization (ESI) source in positive ion multiple reaction monitoring (MRM) mode. Selected ion monitoring transitions of 423.1 → 273.1 and 611.4 → 303.3 were chosen to quantify mangiferin and IS. Biological samples were pretreated via protein precipitation with acetonitrile-acetic acid. The standard calibration curves were above the ranges of 2 to 500 ng·mL and 5 to 2000 ng·mL for tissues, and 1 to 600 ng·mL for plasma. All calibration curves for tissue and plasma samples showed good linearity (r ≥ 0.9974) over the concentration ranges. Intra- and inter-day precisions were <14.0%, and accuracy ranged from 97.2% to 111.7%. The established method was successfully applied on mangiferin tissue distribution following the intragastric administration of mangiferin, Rhizoma Anemarrhenae (A. Rhizoma) decoction, or Rhizoma Anemarrhenae-Phellodendron (herb pair, HP) decoction under healthy or diabetic conditions. Mangiferin was detected from all the tested tissues (except for brain) after monomer administration, and the concentrations were lower compared with the decoction groups. Distributions in the HP group were lower than those in the A. Rhizoma group, but mangiferin content in pancreas was obviously higher than in other tissues and in the A. Rhizoma group. Compared with healthy rats, mangiferin distributions in pancreas and intestine were lower in diabetic rats administered with the same dose of the herb pair, but still higher than those in other tissues. In addition, distributions in liver, spleen, lung, kidney, stomach, and plasma were higher than those in the normal group.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2019.05.019DOI Listing

Publication Analysis

Top Keywords

calibration curves
8
tissue distribution
4
distribution study
4
mangiferin
4
study mangiferin
4
mangiferin intragastric
4
intragastric administration
4
administration mangiferin
4
mangiferin monomer
4
monomer rhizoma
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!