Purpose: To generate 3-dimensional (3D) printed ultrasound (US)-compatible vascular models (3DPVAM) and test them for noninferiority in training medical students in femoral artery access.
Materials And Methods: A 3DPVAM of normal femoral artery (FA) anatomy was developed from an anonymized computerized tomography (CT) examination. Students were randomized to a 3DPVAM or a commercial model (CM) simulation experience (SE) for US-guided FA access. Students completed a pre-SE questionnaire ranking their self-confidence in accessing the artery on a 5-point Likert scale. A standardized SE was administered by interventional radiology faculty or trainees. Students completed a post-SE questionnaire ranking comfort with FA access on a Likert scale. Student questionnaire results from the 3DPVAM group were compared with those from the CM group by using chi-square, Wilcoxon signed-rank, and noninferiority analyses.
Results: Twenty-six and twenty-three students were randomized to 3DPVAM and commercial model training, respectively. A total of 76.9% of 3DPVAM trainees and 82.6% of CM trainees did not feel confident performing FA access prior to the SE. In both groups, training increased student confidence by 2 Likert points (3DPVAM: P < 0.001; CM P < 0.001). The confidence increase in 3DPVAM trainees was noninferior to that in CM trainees (P < 0.001).
Conclusions: Generation of a custom-made 3DPVAM is feasible, producing comparable subjective training outcomes to those of CM. Custom-made 3D-printed training models, including incorporation of more complex anatomical configurations, could be used to instruct medical students in procedural skills.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvir.2019.02.011 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!