Background: Drug-coated balloon as a novel therapeutic strategy has been used to treat restenosis in cases of bare metal and drug-eluting stents. However, evidence of its safety and efficacy is scarce in de novo small coronary artery vessel disease. This meta-analysis aimed to compare the safety and efficacy of the drug-coated balloon and the drug-eluting stent.
Methods: The PubMed, EMBASE, Web of Science, and Cochrane library databases were searched for studies published up to October 17, 2018. Studies comparing the drug-coated balloon with the drug-eluting stent strategy in patients with de novo small coronary artery vessel disease (reference diameter, <3 mm) were identified. The clinical outcomes were nonfatal myocardial infarction, cardiac death, all-cause death, target lesion revascularization, and target-vessel revascularization. Data were analyzed using the statistical software RevMan (version 5.3). Fixed effects models were performed to calculate the pooled odds ratios (ORs) and 95% confidence intervals (95% CIs). Sensitivity analyses were used to detect potential sources of heterogeneity, while subgroup analyses were implemented to assess the differential effects.
Results: Three randomized controlled trials and 3 nonrandomized controlled studies were identified. Six studies including a total of 1800 patients compared the differences between the drug-coated balloon and the drug-eluting stent strategies in patients with de novo small coronary artery vessel disease. The results indicated that the drug-coated balloon strategy was associated with a significant reduction in nonfatal myocardial infarction (OR 0.53, 95% CI 0.31-0.90, P = .02) compared with the drug-eluting stent strategy, while insignificant inter-strategy differences were observed in cardiac death (OR 1.56, 95% CI 0.73-3.33, P = .25), all-cause death (OR 0.56, 95% CI 0.25-1.23, P = .15), target lesion revascularization (OR 1.24, 95% CI 0.73-2.1, P = .43), and target-vessel revascularization (OR 0.95, 95% CI 0.59-1.52, P = .84).
Conclusions: This meta-analysis suggests that the drug-coated balloon strategy is noninferior to the drug-eluting stent strategy, delivering a good outcome in nonfatal myocardial infarction, and can be recommended as an optimal treatment strategy in patients with de novo small coronary artery vessel disease. Larger randomized controlled studies with longer follow-up periods are needed to further confirm the benefits of the drug-coated balloon strategy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6571399 | PMC |
http://dx.doi.org/10.1097/MD.0000000000015622 | DOI Listing |
ACS Biomater Sci Eng
January 2025
Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3E3, Canada.
Restenosis remains a long-standing limitation to effectively maintain functional blood flow after percutaneous transluminal angioplasty (PTA). While the use of drug-coated balloons (DCBs) containing antiproliferative drugs has improved patient outcomes, limited tissue transfer and poor therapeutic targeting capabilities contribute to off-target cytotoxicity, precluding adequate endothelial repair. In this work, a DCB system was designed and tested to achieve defined arterial delivery of an antirestenosis therapeutic candidate, cadherin-2 (N-cadherin) mimetic peptides (NCad), shown to selectively inhibit smooth muscle cell migration and limit intimal thickening in early animal PTA models.
View Article and Find Full Text PDFCardiovasc Diagn Ther
December 2024
GRN Hospital Weinheim, Department of Cardiology, Vascular Medicine & Pneumology, Weinheim, Germany.
Cardiovasc Diagn Ther
December 2024
Department of Cardiology, Dokkyo Medical University Saitama Medical Center, Saitama, Japan.
Cardiovasc Diagn Ther
December 2024
Department of Angiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Am J Cardiol
January 2025
Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
Endovascular treatment of femoropopliteal artery (FPA) disease with Drug-coated balloons (DCBs) may face complications such as arterial recoil, dissection, and residual stenosis. Angiography has limited accuracy for evaluating blood flow through revascularized target lesions. Thus, there is a need for post-procedure hemodynamic assessment in treated limbs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!