Background: Holder pasteurization (HoP) is the recommended method of pasteurization for donor human milk (DHM). The aim of the present study was to compare nutritional and microbiological impact on DHM of a new technique of pasteurization based on technical changes of HoP.

Methods: We analyzed milk samples from 25 donors. Each sample, derived from one breast milk expression, was subdivided into three aliquots according to pasteurization: The first was not pasteurized, the second pasteurized by HoP, and the third was pasteurized by modified HoP (MHoP). Each aliquot was assessed as to its microbiological and nutritional profile. Nutritional profile included calcium and triglycerides concentrations detected by spectrophotometry and amino acid levels assessed by high-performance liquid chromatography (HPLC).

Results: Triglycerides were significantly lower in pasteurized, by both methods, than in not pasteurized aliquots, while calcium and amino acids concentration were similar. Microbiological profile did not differ between HoP and MHoP aliquots.

Conclusions: HoP and MHoP seem to have similar efficacy in preserving some nutritional characteristics of DHM and to confer similar microbiological safety. MHoP is time-saving and potentially costs-effective when compared to HoP, and it is; therefore, potentially of more interest from a practical point of view. Further studies are needed to confirm these findings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6566761PMC
http://dx.doi.org/10.3390/nu11051139DOI Listing

Publication Analysis

Top Keywords

hop mhop
12
holder pasteurization
8
donor human
8
human milk
8
nutritional profile
8
hop
6
pasteurization
5
pasteurized
5
modified holder
4
pasteurization method
4

Similar Publications

Multiplexing is a valuable strategy to boost throughput and improve clinical accuracy. Exploiting the vertical, meshed design of reproducible and low-cost ultra-dense electrochemical chips, the unprecedented single-response multiplexing of typical label-free biosensors is reported. Using a cheap, handheld one-channel workstation and a single redox probe, that is, ferro/ferricyanide, the recognition events taking place on two spatially resolved locations of the same working electrode can be tracked along a single voltammetry scan by collecting the electrochemical signatures of the probe in relation to different quasi-reference electrodes, Au (0 V) and Ag/AgCl ink (+0.

View Article and Find Full Text PDF

Background: It has been recognized that anterior cruciate ligament (ACL) injuries typically occur when athletes are attending to a secondary task or object, including teammates, opponents, and/or a goal. Commonly applied tests after ACL injury include a series of hop tests to determine functional status, yet do not control for visual fixation.

Purpose: To examine the influence of visual fixation during two functional hop tests in healthy individuals.

View Article and Find Full Text PDF

Background: Hop tests are commonly used within a testing battery to assess readiness for return to sport after anterior cruciate ligament (ACL) injury, yet athletes still experience a high rate of re-injury. Simultaneous performance of a secondary task requiring cognitive processing or decision-making may test the athlete under more realistic contexts.

Purpose: To examine a clinically feasible, dual-task assessment paradigm applied during functional hop tests in healthy individuals.

View Article and Find Full Text PDF

Background: Holder pasteurization (HoP) is the recommended method of pasteurization for donor human milk (DHM). The aim of the present study was to compare nutritional and microbiological impact on DHM of a new technique of pasteurization based on technical changes of HoP.

Methods: We analyzed milk samples from 25 donors.

View Article and Find Full Text PDF

Improved fMRI calibration: precisely controlled hyperoxic versus hypercapnic stimuli.

Neuroimage

January 2011

McConnell Brain Imaging Center, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada.

The calibration of functional magnetic resonance imaging (fMRI) for the estimation of neuronal activation-induced changes in cerebral metabolic rate of oxygen (CMRO(2)) has been achieved through hypercapnic-induced iso-metabolic increases in cerebral blood flow (CBF). Hypercapnia (HC) has been traditionally implemented through alterations in the fixed inspired fractional concentrations of carbon dioxide (F(I)CO(2)) without otherwise controlling end-tidal partial pressures of carbon dioxide (P(ET)CO(2)) or oxygen (P(ET)O(2)). There are several shortcomings to the use of this manual HC method that may be improved by using precise targeting of P(ET)CO(2) while maintaining iso-oxia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!