In the present work, a new in-situ prompt gamma-ray neutron activation analysis (PGNAA) setup was developed for the quantitative measurement of chromium (Cr) in aqueous solutions which consists of a 4" × 4″ inch Bismuth Germanate detector and a 300 mCi Americium-beryllium neutron source. A series of standard samples were prepared by dissolving Cr compounds in deionized water of analytical pure grade and measured using the in situ PGNAA setup. Quantitative spectrum analysis was conducted using Monte Carlo Library Least-Squares approach (MCLLS). Simulates of elemental library spectra were in silico modeled using the CEARCPG code, which was developed by Prof. Robin Gardner research group in North Carolina State University. The fitted spectra presented were in excellent agreement with the total experimental spectrum, and the correlation coefficients were all nearly 1. After applying the MCLLS approach, the minimum detectable concentration of Cr was 301.5 mg/L, better than that obtained with other setups, and the relative deviation of the Cr quantitative analysis accuracy was less than 4.09%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2019.02.018DOI Listing

Publication Analysis

Top Keywords

monte carlo
8
carlo library
8
library least-squares
8
mclls approach
8
quantitative analysis
8
pgnaa setup
8
application monte
4
least-squares mclls
4
approach chromium
4
quantitative
4

Similar Publications

Peptide therapeutics, a major class of medicines, have achieved remarkable success across diseases such as diabetes and cancer, with landmark examples such as GLP-1 receptor agonists revolutionizing the treatment of type-2 diabetes and obesity. Despite their success, designing peptides that satisfy multiple conflicting objectives, such as target binding affinity, solubility, and membrane permeability, remains a major challenge. Classical drug development and structure-based design are ineffective for such tasks, as they fail to optimize global functional properties critical for therapeutic efficacy.

View Article and Find Full Text PDF

Mitochondrial DNA (mtDNA) plays a crucial role in numerous cellular processes, yet its impact on human behavior remains underexplored. The current paper proposes a novel covariance structure model with seven parameters to specifically isolate and quantify mtDNA effects on human behavior. This approach uses extended pedigrees to obtain estimates of mtDNA variance while controlling for other genetic and environmental influences.

View Article and Find Full Text PDF

Radiation dose and diagnostic image quality are opposing constraints in x-ray CT. Conventional methods do not fully account for organ-level radiation dose and noise when considering radiation risk and clinical task. In this work, we develop a pipeline to generate individualized organ-specific dose and noise at desired dose levels from clinical CT scans.

View Article and Find Full Text PDF

On the correction factors for small field dosimetry in 1.5T MR-linacs.

Phys Med Biol

January 2025

Medical Physics Laboratory, School of Medicine, National and Kapodistrian University of Athens, 75 Mikras Asias, Goudi, Athens, Attica, 11527, GREECE.

Clinical dosimetry in the presence of a 1.5T magnetic field is challenging, let alone in case small fields are involved. The scope of this study is to determine a set of relevant correction factors for a variety of MR-compatible detectors with emphasis on small fields.

View Article and Find Full Text PDF
Article Synopsis
  • The paper addresses concerns about human health risks from radiation emitted by wireless communication devices in smart vehicles, highlighting that traditional SAR measurement systems aren't suitable for in-vehicle scenarios.
  • It introduces a new SAR measurement system and method tailored for in-vehicle environments, emphasizing the need to evaluate measurement uncertainties due to differences in hardware and methods.
  • The study analyzes the impact of tissue fluid on SAR, establishing fitting models and employing the Monte Carlo Method for uncertainty evaluation, ultimately finding that a quadratic model provides a more accurate representation of the relationship between tissue fluid properties and SAR values.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!