AI Article Synopsis

  • Accurate reference ranges for renal lengths can improve clinical decision-making for children, yet current methods do not consider individual anthropometrics.
  • A study was conducted on 424 children to measure their kidney lengths using ultrasound and develop predictive models, excluding those with familial renal issues or abnormal kidneys.
  • Results showed that both age and physical attributes like height and weight significantly influenced kidney lengths, with notable differences between males and females at younger ages, highlighting the need for gender-specific models.

Article Abstract

Background: Accurate prediction of reference ranges of renal lengths facilitates clinical decision making. Currently a single renal-length-reference chart is used for both kidneys, which is solely based on the age of the child without adjusting for anthropometrics. Objective of the study is to assess the length of morphologically-normal kidneys ultrasonically and to build models to predict the renal lengths of children presenting at the Radiology Department of Lady Ridgeway Hospital for Children.

Methods: A descriptive cross sectional study was done among 424 children with 233 males and 191 females at the study setting. Study population included children undergoing abdominal ultrasound scans for indications not related to renal disease. Children with a family history of renal diseases or with morphologically-abnormal kidneys were excluded. Bipolar-lengths of kidneys, gender and anthropometrics were documented. Having tested for assumptions, Wilcoxon-signed rank test, Mann-Whitney U test and multiple linear regression were used.

Results: The mean (SD) bipor-length of right and left kidneys were 6.83 (1.43) and 7.05 (1.36) respectively (p < 0.001). Age, height and weight were significantly correlated with the renal lengths (p < 0.05). Until 16 months, there was a significant difference between the renal lengths between males and females (P < 0.05). Yet the association with gender was not significant from 17 months and in overall. Until 16 months, the best linear-regression equation (p < 0.001) for the left kidney was; 3.827 +  0.019(length in centimeters) +  0.141(weight in kilograms) - 0.023(age in months) - 0.347(for male sex). For the right kidney, it was; 3.888 + 0.020(length or height) + 0.121(weight) - 0.037(age) - 0.372 (for male sex). The respective R squares were 59.2 and 53.5% with VIF (Variance-Inflation-Factor) ranging from 1.06 to 2.08. From 17 months, best equation for left kidney (p < 0.001) was; 5.651+ 0.022(age) + 0.01(BMI). For right kidney it was; 5.336 + 0.022(age) + 0.012(BMI). The R squares were 62.5 and 66.1% with VIF being 1.

Conclusions: The established models explain more variability for children above 17 months. Both renal lengths are affected significant by the body's' anthropometric parameters. For each kidney, separate normograms of renal lengths which are local-context-specific must be prepared. Further research must be promoted.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6532158PMC
http://dx.doi.org/10.1186/s12882-019-1377-zDOI Listing

Publication Analysis

Top Keywords

length morphologically-normal
8
morphologically-normal kidneys
8
renal lengths
8
kidneys
6
children
5
ultrasonographic length
4
kidneys children
4
children presented
4
presented premier
4
premier tertiary
4

Similar Publications

Article Synopsis
  • The study aimed to evaluate the visibility of the fetal optic chiasm and optic tracts through ultrasound and establish reference values for mid-trimester fetuses.
  • It included 154 normal fetuses at 19-23 weeks of gestation, measuring various dimensions using a specific ultrasound technique, successfully visualizing OC and OTs in 70.8% of cases.
  • Results showed that the dimensions of OC and OTs were positively correlated with measurements of the cavum septum pellucidum, as well as other growth indicators like biparietal diameter and head circumference.
View Article and Find Full Text PDF
Article Synopsis
  • The study evaluates a new technique for preparing an autograft patch from the long head of the biceps to aid in repairing rotator cuff injuries.
  • It involved analyzing tissue samples from patients who underwent biceps tenodesis, comparing compressed and non-compressed samples for signs of tenocyte damage.
  • Results indicate that the compression process did not significantly harm the tenocyte morphology, suggesting it is a safe method for enhancing rotator cuff repairs.
View Article and Find Full Text PDF

(1) Background: Alcohol consumption is one of the main causes of acute pancreatitis. (2) Material and Methods: In this unicentric retrospective cohort study, we selected 1855 patients from the Bucharest Acute Pancreatitis Index (BUC-API) who presented with acute pancreatitis. We investigated correlations between Alcoholic Acute Pancreatitis (AAP) and the rate of complications, cost, length of hospitalization and rate of recurrence.

View Article and Find Full Text PDF

A pilot study of LINE-1 copy number and telomere length with aging in human sperm.

J Assist Reprod Genet

August 2023

Department of Obstetrics and Gynecology, Langone Medical Center, New York University, 462, 1st Avenue, New York, NY, 10016, USA.

Purpose: Unlike other cells in the body, in sperm, telomere length (TL) increases with age. TL can regulate nearby genes, and the subtelomeric region is rich in retrotransposons. We hypothesized that age-related telomere lengthening in sperm might suppress Long Interspersed Element 1 (LINE-1/L1), the only competent retrotransposon in humans.

View Article and Find Full Text PDF

Morphological sperm evaluation supported by the morphometry can be used in the determination of the seminal quality and in the investigation of potential extenders. Although there are studies comparing TRIS and ACP extenders, there are no comparative studies between them for the computerized assisted semen analysis (CASA), sperm viability, membrane functionality and sperm morphometry parameters of cryopreserved canine semen. Hence, we aimed to evaluate the effects of ACP-106c and TRIS on post-freezing canine sperm quality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!