A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The earliest timing of ultrasound in screening for developmental dysplasia of the hips. | LitMetric

The earliest timing of ultrasound in screening for developmental dysplasia of the hips.

Ultrasonography

Department of Orthopaedic Surgery, University Orthopaedic, Hand and Reconstructive Microsurgery Cluster, National University Health System (NUHS), Singapore.

Published: October 2019

Purpose: The current study aimed to evaluate the results of ultrasound screening for developmental dysplasia of the hips (DDH) done at various weeks of life, to determine the earliest time that ultrasound screening can be performed reliably.

Methods: In this 17-year cohort study, all neonates who underwent ultrasound screening prior to the 12th week of life with subsequent follow-up radiography done at 1 year of life were included. The ultrasound images were evaluated according to the Graf classification, Harcke's dynamic ultrasound screening method, and Terjesen's femoral head coverage method. The radiographic images were evaluated according to the acetabular index and the femoral head position. The accuracy and correlation between the ultrasound findings from various weeks of life with the radiographic findings at 1 year of life were evaluated.

Results: A total of 348 neonates were included in the study, of whom 92 had abnormal ultrasound findings and 42 had abnormal radiographic findings at 1 year. Significant differences were identified between the findings of ultrasound screening examinations performed prior to the fourth week of life (day 21 and before) and the radiographic findings at 1 year of life (P<0.05). In contrast, no significant differences were identified when ultrasound screening was performed between the fourth and 12th weeks of life (day 22 and beyond) (P>0.05). The accuracy of ultrasound screening was 79.2% or higher when performed during or after the fourth week of life (day 22 and beyond).

Conclusion: The earliest that ultrasound screening for DDH can be performed reliably is during the fourth week of life (day 22 and beyond).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6769192PMC
http://dx.doi.org/10.14366/usg.18075DOI Listing

Publication Analysis

Top Keywords

ultrasound screening
32
week life
16
year life
12
radiographic findings
12
findings year
12
fourth week
12
life day
12
ultrasound
11
life
9
screening
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!