AI Article Synopsis

  • This study explores the contrast-to-noise ratios (CNRs) of structural and functional measurements to evaluate their effectiveness in detecting glaucoma progression.
  • Researchers calculated CNRs for retinal nerve fiber layer (RNFL) thickness and visual field parameters, using data from healthy and glaucomatous eyes over five stages of the disease.
  • Results showed RNFL thickness was more sensitive in early glaucoma stages, while functional measures like mean deviation (MD) and visual field index (VFI) became more effective in later stages, indicating a shift in what to monitor as glaucoma progresses.

Article Abstract

Purpose: We determine the contrast-to-noise ratios (CNRs) of structural and functional measurements to assess their sensitivity to detect progression in the various stages of glaucoma.

Methods: We calculated the CNRs for the mean peripapillary retinal nerve fiber layer (RNFL) thickness measured by spectral domain optical coherence tomography, and the mean deviation (MD) and visual field index (VFI) determined by standard automated perimetry for the transitions between five stages. Longitudinal data from healthy and glaucomatous eyes from a prospective study were used. Contrast was defined as the change in the mean value of the parameter between two successive stages. Noise was defined as the variability of the parameter and calculated from the residuals of linear regression on the data from five subsequent visits per eye.

Results: We studied 205 eyes from 125 participants (46% men, 54% women). CNRs for different parameters varied considerably across the range of disease severity (0.8-12.2). The RNFL thickness had a higher CNR in the transition from normal to mild glaucoma (12.2) compared to the CNRs of the functional measures (MD 4.1, VFI 4.5). The CNRs for the functional measures were higher in the transition from moderate to advanced (MD 5.2, VFI 5.8) and advanced to severe glaucoma (MD 7.2, VFI 5.8) compared to the RNFL thickness (CNR 0.8 and 3.2, respectively).

Conclusions: The RNFL thickness is more sensitive for detecting glaucomatous progression at the onset of glaucoma compared to the functional measures, while the latter are more sensitive for detecting progression in the later stages of glaucoma.

Translational Relevance: The CNR method can be used to determine which measurement is most sensitive for detecting progression in glaucoma, differentiated for the severity of the disease. Furthermore, it creates a basic toolset for determining the most sensitive measurement in detecting progression not only in glaucoma, but other (ophthalmic) diseases as well.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6504842PMC
http://dx.doi.org/10.1167/tvst.8.3.8DOI Listing

Publication Analysis

Top Keywords

rnfl thickness
16
progression stages
12
functional measures
12
sensitive detecting
12
detecting progression
12
contrast-to-noise ratios
8
cnrs functional
8
progression glaucoma
8
progression
6
glaucoma
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!