AI Article Synopsis

  • The discovery of thrombosis in transcatheter heart valves (THVs) raises concerns about their long-term durability, with low-velocity blood flow potentially being a key factor.
  • A new single camera volumetric velocimetry technique has been developed to measure unsteady three-dimensional cardiovascular flows, validating its effectiveness by comparing it to standard planar particle image velocimetry (PIV).
  • The study revealed significant flow stagnation around the THV, suggesting that low shear stress could contribute to thrombosis, paving the way for better understanding and modeling of heart valve thrombosis.

Article Abstract

The recent unexpected discovery of thrombosis in transcatheter heart valves (THVs) has led to increased concerns of long-term valve durability. Based on the clinical evidence combined with Virchow's triad, the primary hypothesis is that low-velocity blood flow around the valve could be a primary cause for thrombosis. However, due to limited optical access in such unsteady three-dimensional biomedical flows, measurements are challenging. In this study, for the first time, we employ a novel single camera volumetric velocimetry technique to investigate unsteady three-dimensional cardiovascular flows. Validation of the novel volumetric velocimetry technique with standard planar particle image velocimetry (PIV) technique demonstrated the feasibility of adopting this new technique to investigate biomedical flows. This technique was used to quantify the three-dimensional velocity field in the vicinity of a validated, custom developed, transparent THV in a bench-top pulsatile flow loop. Large volumetric regions of flow stagnation were observed in the neo-sinus throughout the cardiac cycle, with stagnation defined as a velocity magnitude lower than 0.05 m s. The volumetric scalar viscous shear stress quantified via the three-dimensional shear stress tensor was within the range of low shear-inducing thrombosis observed in the literature. Such high-fidelity volumetric quantitative data and novel imaging techniques used to obtain it will enable fundamental investigation of heart valve thrombosis in addition to providing a reliable and robust database for validation of computational tools.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6544900PMC
http://dx.doi.org/10.1098/rsif.2019.0063DOI Listing

Publication Analysis

Top Keywords

flow stagnation
8
transcatheter heart
8
heart valves
8
unsteady three-dimensional
8
biomedical flows
8
volumetric velocimetry
8
velocimetry technique
8
technique investigate
8
shear stress
8
three-dimensional
5

Similar Publications

Background: Traumatic intracranial aneurysms (TICAs) can be fatal if ruptured. We report a case of a TICA, distant from facial bone fractures, successfully treated with flow diverter (FD) before rupture.

Case Presentation: A 20-year-old woman was admitted following a car accident.

View Article and Find Full Text PDF

Background: Intrasaccular flow diversion using the woven endobridge device (WEB; MicroVention, Aliso Viejo, CA, USA) for the treatment of intracranial aneurysms has demonstrated large scale safety and efficacy. However, limitations arise from its structural configuration, restricting its application to specific aneurysm sizes and shapes.

Technique Overview: We introduce the CUPCAKE technique, a combination of conventional coiling followed by WEB intrasaccular flow disruption in select cases of atypical aneurysms with technically challenging morphology not typically treatable by WEB alone.

View Article and Find Full Text PDF

Coil embolization of cerebral aneurysms often encounters challenges in achieving complete filling of the aneurysm sac due to complex shapes and hemodynamic factors, frequently resulting in the formation of a residual cavity (RC) at the aneurysm neck. The hemodynamic mechanisms underlying RC formation and growth, however, remain poorly understood. Computational fluid dynamics (CFD) analysis, combined with silent MRA free from contrast agents and metal artifacts, offers a promising approach to elucidate these mechanisms, potentially enhancing the clinical management of cerebral aneurysms post-coiling.

View Article and Find Full Text PDF

[Professor 's clinical experience in treatment of pelvic congestion syndrome with acupuncture].

Zhongguo Zhen Jiu

January 2025

Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Sciences, Beijing 100700, China; Acupuncture and Moxibustion Hospital of China Academy of Chinese Medical Sciences, Beijing 100700.

The paper introduces Professor 's experience in treating pelvic congestion syndrome with acupuncture. Professor believes that the stagnation in the thoroughfare and conception vessels, retarded circulation of and blood, and the obstruction of blood flow in the uterus are implicated in the pathogenesis of pelvic congestion syndrome. In clinical practice, according to the pathogenesis, focusing on regulating the functions of the thoroughfare and conception vessels, the thinking of treatment is summarized as "resolving the stasis and stopping pain by regulating the thoroughfare and conception vessels", "selecting the points based on their indications" and "tranquilizing the mind and harmonizing the physical and mental states".

View Article and Find Full Text PDF

Introducing pulsatility in LVADs is known to reduce complications such as stagnation and thrombosis, but it is an ongoing topic of research on what the optimal form is. We present a framework consisting of parametrized full-order simulations, reduced-order models, and sensitivity analysis to systematically quantify the effects of parametrized pulsatility on washout. As a sample problem, we study the washout in an idealized 2D left ventricle and a parametrized sinusoidal LVAD flow rate.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!