A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Relationships Between Radiation Exposure Dose, Time, and Projection in Videofluoroscopic Swallowing Studies. | LitMetric

Purpose Clinicians are trained to rely on radiation exposure time as an indicator of patient radiation exposure in Videofluoroscopic Swallowing Studies (VFSSs). However, it has been shown in other medical uses of fluoroscopy that dose area product (DAP), the amount of radiation delivered to the patient, is a better indicator of overall patient radiation exposure than radiation exposure time. This study sought to understand the relationship of DAP in VFSSs with radiation exposure time and projection used (lateral vs. posterior-anterior [PA]). Method DAP, radiation exposure time, and projection were recorded in 200 adults undergoing clinically indicated VFSSs conducted in accordance with the Modified Barium Swallow Impairment Profile guidelines. Data were analyzed using Spearman correlation and related sample Wilcoxon test. Results DAP and radiation exposure time did not correlate significantly in the lateral or upper PA projections. DAP was significantly higher in the PA compared to lateral projection (p < .01); however, time was shorter in PA versus lateral (p < .01). The average mGy-cm per second was 7 for lateral projections, 14 for upper PA projections, 17 for middle PA projections, and 34 for lower PA projections. Conclusions Radiation exposure time and DAP do not strongly correlate across VFSSs. Specifically, this means that 1 patient can have a low radiation exposure time with a high DAP relative to another person with a higher radiation exposure time but a lower DAP. The results of this study question the common clinical practice of using time (specifically the 5-min indicator) as a threshold for radiation exposure during a VFSSs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6802925PMC
http://dx.doi.org/10.1044/2019_AJSLP-18-0271DOI Listing

Publication Analysis

Top Keywords

radiation exposure
48
exposure time
32
exposure
12
time projection
12
radiation
12
time
11
videofluoroscopic swallowing
8
swallowing studies
8
indicator patient
8
patient radiation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!