3-D Contrast-Enhanced Ultrasound Fusion Imaging: A New Technique to Evaluate the Ablative Margin of Radiofrequency Ablation for Hepatocellular Carcinoma.

Ultrasound Med Biol

Division of Interventional Ultrasound, Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China. Electronic address:

Published: August 2019

To investigate the feasibility of assessing the ablative margin (AM) of radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC) with 3-D contrast-enhanced ultrasound fusion imaging (3-DCEUS-FI), pre- and post-RFA 3-DCEUS images of 84 patients with HCC were fused for two radiologists to independently assess the AMs. The success rate, duration and influencing factors for registration; inter-observer agreement for AM classification; and local tumor progression (LTP) rate were evaluated. The success rate of the automatic registration (AR), which was completed within 4-12 s, was 57.1% (48/84). The duration and success rate of the interactive registration (IR) were 4.2 ± 1.8 min and 91.7% (77/84) for radiologist A and 4.8 ± 2.1 min and 91.7% (77/84) for radiologist B, respectively. The multivariate analysis demonstrated that the pre-RFA image quality, number of vessels (≥3 mm) and presence of acoustic shadow were independent factors for AR (p < 0.05), while the number of vessels was an independent factor for IR (p = 0.001). The agreement between observers was excellent (kappa = 0.914). LTP rate was significantly higher for AMs <5 mm than for AMs ≥5 mm (p = 0.024). Quantitatively evaluating the AM immediately after RFA for HCC with 3-DCEUS-FI was feasible.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2019.03.019DOI Listing

Publication Analysis

Top Keywords

success rate
12
3-d contrast-enhanced
8
contrast-enhanced ultrasound
8
ultrasound fusion
8
fusion imaging
8
ablative margin
8
margin radiofrequency
8
radiofrequency ablation
8
hepatocellular carcinoma
8
ltp rate
8

Similar Publications

Introduction: In hospital-based emergency departments, the national average of left before treatment complete was 2%. In addition, patients may leave without being seen or against medical advice and elope after arriving to the emergency department. When events occurred, they were associated with an increased length of stay for patients who were admitted to the hospital and decreased patient satisfaction.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the long-term efficacy of the ligation of the intersphincteric fistula tract (LIFT) procedure in treating high transsphincteric fistulas.

Methods: We conducted a retrospective study to evaluate the success rate of LIFT treatment in 82 patients with high transsphincteric fistulas involving at least 1/3 of the external sphincter. This study was carried out across 2 centers from November 2009 to February 2023.

View Article and Find Full Text PDF

Ultrasound-guided intercostal nerve injection in rabbit cadavers: Technique description and comparison with blind approach.

Vet Anaesth Analg

December 2024

Department of Comparative Diagnostic, and Population Medicine, College of Veterinary Medicine, University of Florida, Gainesville, FL, USA. Electronic address:

Objective: To develop an ultrasound-guided technique for intercostal nerve blocks in rabbit cadavers and to compare the success rate and potential complications of this technique to blind injection.

Study Design: Prospective, randomized, blinded, descriptive experimental cadaveric study.

Animals: A group of nine adult domestic rabbit cadavers (body mass 1.

View Article and Find Full Text PDF

Background: Although the method of autocalibration or calibration based on catheter diameters was proposed for fluoroscopic measurement during percutaneous left atrial appendage occlusion (LAAO), it may be imprecise and lead to mismeasurement. We sought to investigate whether the utilization of the surface steel ball calibration (SSBC) method under fluoroscopy could facilitate the fluoroscopic measurement of the post-implanted WATCHMAN device (Boston Scientific Corporation, Natick, MA, USA) in LAAO.

Methods: This retrospective study included 97 consecutive patients who underwent percutaneous LAAO with the WATCHMAN device.

View Article and Find Full Text PDF

A simple acetylcholinesterase inhibition assay for the quantification of the nerve agent VX: Application in a Franz cell model with rat skin and various decontaminants.

Toxicol Lett

January 2025

Bundeswehr Institute of Pharmacology and Toxicology, Neuherbergstrasse 11, 80937 Munich, Germany; Walther-Straub-Institute of Pharmacology and Toxicology, Faculty of Medicine, Ludwig-Maximilians-Universität München, Goethestrasse 33, 80336 Munich, Germany. Electronic address:

The medical community continues to regard organophosphate nerve agent poisoning as a significant concern. Due to the lack of therapeutic options for the nicotinic signs and symptoms for certain agents (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!