A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Colour Doppler ultrasound after major cardiac surgery improves diagnostic accuracy of the pulmonary infection score in acute respiratory failure: A prospective observational study. | LitMetric

Background: Postoperative pneumonia is a frequent complication after cardiac surgery, and its diagnosis is difficult. Little is known about the diagnostic accuracy of lung ultrasound (LUS) in the detection of pneumonia in cardiac surgical patients. The substitution of chest radiography by colour Doppler LUS (LUS-sCPIS) in the simplified clinical pulmonary infection score (sCPIS) could improve the diagnosis of pneumonia following cardiac surgery.

Objective: The aim of this study was to compare the diagnostic accuracy of LUS-sCPIS and of sCPIS alone in the detection of postoperative pneumonia after cardiac surgery.

Design: A prospective study of diagnostic accuracy.

Setting: A Surgical Intensive Care Unit of a French University Hospital.

Patients: Fifty-one patients with acute respiratory failure within 72 h after cardiac surgery were enrolled between January and May 2015.

Main Outcome Measure: The two index tests, LUS-sCPIS and sCPIS, were calculated for all patients at the onset of acute respiratory failure. The reference standard for the diagnosis of pneumonia was based on the consensus of three physicians, blind to the sCPIS and LUS-sCPIS data, based on a posthoc review of all the clinical, radiological and microbiological evidence. The diagnostic accuracy of LUS-sCPIS was compared with that of sCPIS in the detection of postoperative pneumonia.

Results: Pneumonia was diagnosed in 26 out of 51 patients. The LUS-sCPIS detected the presence of pneumonia with a sensitivity of 92% (95% CI 0.85 to 0.99) and a specificity of 68% (95% CI 0.55 to 0.81). The sCPIS detected the presence of pneumonia with a sensitivity of 35% (95% CI 0.22 to 0.48) and a specificity of 84% (95% CI 0.74 to 0.94). The area under the curve (AUC) of LUS-sCPIS at 0.80 (95% CI 0.69 to 0.91) was higher than the AUC of sCPIS at 0.59 (95% CI 0.47 to 0.71; P = 0.0008).

Conclusion: Compared with sCPIS, LUS-sCPIS improved diagnostic accuracy in the detection of postoperative pneumonia in patients with acute respiratory failure after cardiac surgery. It could be a useful bedside tool to guide pneumonia management.

Trial Registration: Clinicaltrials.gov identifier: NCT03279887.

Download full-text PDF

Source
http://dx.doi.org/10.1097/EJA.0000000000001022DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
20
cardiac surgery
16
acute respiratory
16
respiratory failure
16
postoperative pneumonia
12
pneumonia cardiac
12
detection postoperative
12
pneumonia
10
colour doppler
8
pulmonary infection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!