Background: A velocity offset error in phase contrast cardiovascular magnetic resonance (CMR) imaging is a known problem in clinical assessment of flow volumes in vessels around the heart. Earlier studies have shown that this offset error is clinically relevant over different systems, and cannot be removed by protocol optimization. Correction methods using phantom measurements are time consuming, and assume reproducibility of the offsets which is not the case for all systems. An alternative previously published solution is to correct the in-vivo data in post-processing, interpolating the velocity offset from stationary tissue within the field-of-view. This study aims to validate this interpolation-based offset correction in-vivo in a multi-vendor, multi-center setup.

Methods: Data from six 1.5 T CMR systems were evaluated, with two systems from each of the three main vendors. At each system aortic and main pulmonary artery 2D flow studies were acquired during routine clinical or research examinations, with an additional phantom measurement using identical acquisition parameters. To verify the phantom acquisition, a region-of-interest (ROI) at stationary tissue in the thorax wall was placed and compared between in-vivo and phantom measurements. Interpolation-based offset correction was performed on the in-vivo data, after manually excluding regions of spatial wraparound. Correction performance of different spatial orders of interpolation planes was evaluated.

Results: A total of 126 flow measurements in 82 subjects were included. At the thorax wall the agreement between in-vivo and phantom was - 0.2 ± 0.6 cm/s. Twenty-eight studies were excluded because of a difference at the thorax wall exceeding 0.6 cm/s from the phantom scan, leaving 98. Before correction, the offset at the vessel as assessed in the phantom was - 0.4 ± 1.5 cm/s, which resulted in a - 5 ± 16% error in cardiac output. The optimal order of the interpolation correction plane was 1st order, except for one system at which a 2nd order plane was required. Application of the interpolation-based correction revealed a remaining offset velocity of 0.1 ± 0.5 cm/s and 0 ± 5% error in cardiac output.

Conclusions: This study shows that interpolation-based offset correction reduces the offset with comparable efficacy as phantom measurement phase offset correction, without the time penalty imposed by phantom scans.

Trial Registration: The study was registered in The Netherlands National Trial Register (NTR) under TC 4865 . Registered 19 September 2014. Retrospectively registered.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526620PMC
http://dx.doi.org/10.1186/s12968-019-0538-3DOI Listing

Publication Analysis

Top Keywords

offset correction
20
interpolation-based offset
12
thorax wall
12
offset
11
correction
10
phantom
9
phase offset
8
cardiovascular magnetic
8
magnetic resonance
8
multi-vendor multi-center
8

Similar Publications

Objective: Malalignment following cervical spine deformity (CSD) surgery can negatively impact outcomes and increase complications. Despite the growing ability to plan alignment, it remains unclear whether preoperative goals are achieved with surgery. The objective of this study was to assess how good surgeons are at achieving their preoperative goal alignment following CSD surgery.

View Article and Find Full Text PDF

Association between social jetlag and anxiety symptoms: Findings from a nationally representative sample of the Korean working population.

Sleep Med

December 2024

The Institute for Occupational Health, Yonsei University College of Medicine, Seoul, Republic of Korea; Department of Preventive Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea. Electronic address:

Objectives: Social jetlag (SJL), which arises from the misalignment of biological and social rhythms, is associated with adverse health outcomes. We explored the association between SJL and anxiety symptoms in Korean workers.

Methods: This cross-sectional study included a nationally representative sample, consisting of 2731 adult workers.

View Article and Find Full Text PDF

We experimentally demonstrate a cost-effective dual-polarization quadrature phase shift keying (DP-QPSK) coherent passive optical network (PON) system that operates at 100 Gbits/s/λ. This system utilizes distributed feedback lasers (DFBs) and a carrier recovery algorithm facilitated by a bifunctional frequency-domain pilot tone (FPT). To reduce costs in coherent PON implementations, low-cost DFBs are employed as the sole light sources, replacing the more expensive external cavity lasers (ECLs) at both the optical line terminal (OLT) and the optical network units (ONUs).

View Article and Find Full Text PDF

Purpose: To assess the radiological outcomes and complications focusing on distal junctional failure (DJF) of adult spinal deformity patients who underwent thoracolumbar fixation with the use of offset sublaminar hooks (OSH) distally.

Methods: Retrospective review of a prospective, multicenter adult spinal deformity database (2 sites). Inclusion criteria were age of at least 18 years, presence of a spinal deformity with thoraco-lumbar instrumentation ending distally with OSH (pelvis excluded), with minimum 2 years of follow-up.

View Article and Find Full Text PDF

Lockie, RG, Young, MA, Lanham, SN, Orr, RM, Dawes, JJ, and Nagel, TR. Scenario and shooting performance in incumbent deputy sheriffs/police officers, cadets, and cadets who worked in custody/corrections facilities. J Strength Cond Res XX(X): 000-000, 2024-Job-specific fitness of law enforcement personnel can decline during their careers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!