The Indian capital Delhi experienced an environmental emergency in early November 2017 when levels of toxic PM particles surpassed WHO guidelines by 25 times (11 times by Indian Standards) for a prolonged period of a week (peak 24 h average ~650 μg/m). We hereby demonstrate the role that monsoon dynamics played in linking and mixing dust emitted from a large natural dust storm, 3000 km away in the Middle East, with smoke from agriculture fires in northwest India. This dust and smoke rich air was then transported to Delhi where, under stagnant conditions, it mixed with local emissions resulting in very high pollution levels. The heavy aerosol-laden air altered the land-skin surface air temperature difference resulting in increased surface wind speeds, favouring faster dispersion and an unusual sharp decline in PM (PM-110 μg/m). Understanding the multi-scale nature of such events is important in improving our abilities to forecast these events and in developing effective air quality management strategies for the mega cities.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2019.04.347DOI Listing

Publication Analysis

Top Keywords

air quality
8
air
5
anatomy winter
4
winter 2017
4
2017 air
4
quality emergency
4
emergency delhi
4
delhi indian
4
indian capital
4
capital delhi
4

Similar Publications

Introduction: Short-term exposure to air pollution may worsen the course of ischemic heart disease (IHD), causing acute and chronic coronary syndromes.

Objectives: This study aimed to assess the risk of hospital admission due to chronic and acute coronary syndromes (ACS) after exposure to various air pollutants in Poland.

Methods: In this time-series study, the risk of hospital admission due to IHD over 3 days from exposure to several air pollutants was evaluated.

View Article and Find Full Text PDF

Promising mass spectrometry imaging: exploring microscale insights in food.

Crit Rev Food Sci Nutr

January 2025

State Key Laboratory of Marine Food Processing and Safety Control, College of Food Science and Engineering, Ocean University of China, Qingdao, China.

This review focused on mass spectrometry imaging (MSI), a powerful tool in food analysis, covering its ion source schemes and procedures and their applications in food quality, safety, and nutrition to provide detailed insights into these aspects. The review presented a detailed introduction to both commonly used and emerging ionization sources, including nanoparticle laser desorption/ionization (NPs-LDI), air flow-assisted ionization (AFAI), desorption ionization with through-hole alumina membrane (DIUTHAME), plasma-assisted laser desorption ionization (PALDI), and low-temperature plasma (LTP). In the MSI process, particular emphasis was placed on quantitative MSI (QMSI) and super-resolution algorithms.

View Article and Find Full Text PDF

Enhancing Droplet Spreading on a Hydrophobic Plant Surface by Surfactant/Cellulose Nanocrystal Complexes.

ACS Nano

January 2025

Department of Chemical Engineering, Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.

A surfactant is an efficient and common additive used to enhance the spreading of droplets on hydrophobic surfaces. However, a high surfactant concentration is required to achieve the desired performance, resulting in environmental pollution and increased costs. Additionally, the pesticide loading capacity of surfactants at low concentrations (below their critical micelle concentrations) is a concern.

View Article and Find Full Text PDF

Atmospheric Deposition of Microplastics in South Central Appalachia in the United States.

ACS EST Air

January 2025

Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States.

Due to the increased prevalence of plastic pollution globally, atmospheric deposition of microplastics (MPs) is a significant issue that needs to be better understood to identify potential consequences for human health. This study is the first to quantify and characterize atmospheric MP deposition in the Eastern United States. Passive sampling was conducted at two locations within the Eastern United States, specifically in remote South Central Appalachia, from March to September 2023.

View Article and Find Full Text PDF

Spatiotemporal Mapping of Ultrafine Particle Fluxes in an Office HVAC System with a Diffusion Charger Sensor Array.

ACS EST Air

January 2025

Lyles School of Civil & Construction Engineering, Purdue University, West Lafayette, Indiana 47907, United States.

Commercial HVAC systems intended to mitigate indoor air pollution are operated based on standards that exclude aerosols with smaller diameters, such as ultrafine particles (UFPs, D ≤ 100 nm), which dominate a large proportion of indoor and outdoor number-based particle size distributions. UFPs generated from occupant activities or infiltrating from the outdoors can be recirculated and accumulate indoors when they are not successfully filtered by an air handling unit. Monitoring UFPs in real occupied environments is vital to understanding these source and mitigation dynamics, but capturing their rapid transience across multiple locations can be challenging due to high-cost instrumentation.