Implant debris generated by wear and corrosion is a prominent cause of joint replacement failure. This study utilized Fourier transform infrared spectroscopic imaging (FTIR-I) to gain a better understanding of the chemical structure of implant debris and its impact on the surrounding biological environment. Therefore, retrieved joint capsule tissue from five total hip replacement patients was analyzed. All five cases presented different implant designs and histopathological patterns. All tissue samples were formalin-fixed and paraffin-embedded. Unstained, 5 μm thick sections were prepared. The unstained sections were placed on BaF windows and deparaffinized with xylene prior to analysis. FTIR-I data were collected at a spectral resolution of 4 cm using an Agilent Cary 670 spectrometer coupled with Cary 620 FTIR microscope. The results of study demonstrated that FTIR-I is a powerful tool that can be used complimentary to the existing histopathological evaluation of tissue. FTIR-I was able to distinguish areas with different cell types (macrophages, lymphocytes). Small, but distinct differences could be detected depending on the state of cells (viable, necrotic) and depending on what type of debris was present (polyethylene [PE], suture material, and metal oxides). Although, metal oxides were mainly below the measurable range of FTIR-I, the infrared spectra of tissues exhibited noticeable difference in their presence. Tens of micrometer sized polyethylene particles could be easily imaged, but also accumulations of submicron particles could be detected within macrophages. FTIR-I was also able to distinguish between PE debris, and other birefringent materials such as suture. Chromium-phosphate particles originating from corrosion processes within modular taper junctions of hip implants could be identified and easily distinguished from other phosphorous materials such as bone. In conclusion, this study successfully demonstrated that FTIR-I is a useful tool that can image and determine the biochemical information of retrieved tissue samples over tens of square millimeters in a completely label free, nondestructive, and objective manner. The resulting chemical images provide a deeper understanding of the chemical nature of implant debris and their impact on chemical changes of the tissue within which they are embedded.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7388152 | PMC |
http://dx.doi.org/10.1002/jbm.b.34408 | DOI Listing |
Biomedicines
January 2025
Department of Orthopedic Surgery, Faculty of Medicine, Graduate School of Medicine, Hokkaido University, Kita-15, Nish-7, Kita-ku, Sapporo 060-8638, Japan.
Periprosthetic osteolysis is the primary cause of arthroplasty failure in the majority of patients. Mechanistically, wear debris released from the articulating surfaces of a prosthesis initiates local inflammation and several modes of regulated cell death programs, such as ferroptosis, which represents a promising therapeutic target in various chronic inflammatory diseases. Thus, the current study aimed at exploring the therapeutic potential of targeting ferroptosis in a polyethylene-wear-debris-induced osteolysis model.
View Article and Find Full Text PDFCureus
December 2024
Department of Orthopedic Surgery, Japanese Red Cross Shizuoka Hospital, Shizuoka, JPN.
Total hip arthroplasty (THA) is a highly effective surgical intervention for end-stage hip joint disorders. While common complications such as infection, dislocation, and prosthetic loosening are well-documented, rarer complications remain underreported. One such complication is foreign body interposition on the bearing surface, which can compromise joint mechanics and adversely affect outcomes.
View Article and Find Full Text PDFRecent interest has been focused on extracellular matrix (ECM)-based scaffolds totreat critical-sized bone injuries. In this study, urea was used to decellularize and solubilize human placenta tissue. Then, different concentrations of ECM were composited with 8% alginate (Alg) and 12% silk fibroin (SF) for printing in order to produce a natural 3D construct that resembled bone tissue.
View Article and Find Full Text PDFJ Clin Med
January 2025
Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, 8401 Winterthur, Switzerland.
Wear particle reaction is present in every arthroplasty. Sometimes, this reaction may lead to formation of large pseudotumors. As illustrated in this case, the volume of the reaction may be out of proportion to the volume of the wear scar.
View Article and Find Full Text PDFJ Craniofac Surg
January 2025
Department of Plastic and Reconstructive Surgery, Saitama Medical University International Medical Center.
This study aimed to develop a novel reconstruction method for segmental mandibulectomy. In the authors' opinion, reconstruction of the anterior border of the mandibular ramus using a double-arm vascularized fibular flap is important to prevent deformity due to buccal depression and the accumulation of food debris, thereby eliminating masticatory dead space that cannot be filled with prostheses such as implants or dentures. Using conventional reconstruction plates, the reconstructed bone positioned at the anterior border of the mandibular ramus required either fixing with only 1 screw or using 2 plates for stable fixation, making it difficult to position the plates stably.