Background And Objective: The number of laparoscopic procedures increases annually with an estimated 3% of complications, one third of them linked to Verres' needle or trocar insertion. The safety and efficacy of ports insertion during laparoscopic surgery may be related the technique but also to trocar design. This study aims to compare physical parameters of abdominal wall penetration for 5 different trocars.

Methods: Eleven pigs were studied. Five different commercially available trocars were randomically inserted at the midline. Real-time video recording of the insertions was achieved to measure the excursion of the abdominal wall and the time and distance the cutting surface of the bladed trocars was exposed inside the abdominal cavity. An especially designed hand sensor was developed and placed between the trocar and the hand of the surgeon to record force required for abdominal wall perforation.

Results: Greater deformations and forces occurred in nonbladed as compared to bladed trocars, and in conical trocars as compared to pyramidal pointed ones, except for peritoneum perforation. Greater distance and time of blade exposure occurred in pyramidal laminae as compared to conical.

Conclusion: The bladed trocars have lower forces and deformations in their introduction, and should be those that cause less injury and are more suitable for first entry. Conical and pyramidal trocars with the same blade size showed similar force, deformation, time, and distance of exposed blade.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6476561PMC
http://dx.doi.org/10.4293/JSLS.2019.00002DOI Listing

Publication Analysis

Top Keywords

abdominal wall
12
bladed trocars
12
time distance
8
trocars
7
laparoscopic insertion
4
insertion shaped
4
shaped trocars
4
trocars porcine
4
porcine model
4
model background
4

Similar Publications

Incisional ventral hernia repair remains a challenging surgery for abdominal wall surgeons. We report the results at 48 months post-surgery regarding open ventral hernia repair (OVHR), analyzing the recurrence rate and incidence of chronic pain. This was a retrospective, observational study of 111 consecutive patients who underwent OVHR.

View Article and Find Full Text PDF

Abdominal wall endometriosis (AWE) is a clinical disorder with unknown pathogenesis with an incidence between 0.03% and 1% in women affected by cutaneous/scar endometriosis. We investigated the pathological, molecular cytogenetic and cell proliferation features of a primary AWE developed in rectus abdominis muscle in a patient without co-existing pelvic endometriosis.

View Article and Find Full Text PDF

Ultrasound Features of -Related Gastritis.

Antibiotics (Basel)

December 2024

Division of Gastroenterology & Endoscopy, IRCCS, Fondazione "Casa Sollievo della Sofferenza", 71013 San Giovanni Rotondo, Italy.

Abdominal ultrasound (US) is a reliable method for visualizing gastric wall layers and measuring their thickness. The objective of this study is to characterize the ultrasound features of -induced gastritis and assess its predictive potential role for this condition. A cohort of 119 patients underwent gastroscopy with biopsy and abdominal US to evaluate antral wall thickness (AWT), submucosal wall thickness (SLT), mucosal wall thickness (MLT), gastric motility, and the presence of ingested material.

View Article and Find Full Text PDF

Abdominal Ultrasonography in Healthy Female Standard Donkeys.

Animals (Basel)

January 2025

School of Biosciences and Veterinary Medicine, University of Camerino, Via Circonvallazione, 93/95, 62024 Matelica, Italy.

Knowledge of the normal ultrasound anatomy in the donkey is essential to understand pathological changes and to reach an early diagnosis, considering the "dullness" and stoicism of these animals in pain manifestations. The aims of this study were to document which abdominal viscera could be identified using a transcutaneous ultrasonography technique under field conditions in unsedated, standing donkeys to determine where the different abdominal structures could be easily displayed and to describe any variation that occurred between different donkeys and horses. In this work, the manual technique for performing an ultrasound of the abdominal organs in a donkey is described, including acoustic windows.

View Article and Find Full Text PDF

: Microsatellite-stable (MSS) and microsatellite-instable (MSI) colon cancer (CC) cases have different characteristics. These characteristics may impact the accuracy of abdominal computed tomography (CT) scan examinations in MSI CC. : A retrospective analysis was conducted to examine the effects of MSI CC on patients' clinical and tumor characteristics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!