Purpose: To evaluate the efficacy of SmartMouth Clinical DDS compared with 0.12% chlorhexidine and placebo mouthrinses.
Materials And Methods: Seventy-six subjects with gingivitis or chronic periodontitis were enrolled in a double-blind, placebo-controlled, clinical study. Examinations included Gingival Index (GI), Bleeding Score (BS), Plaque Index (PI), Tooth Stain Index (TSI), and Calculus Index (CI). Subjects were given a prophylaxis and oral hygiene instructions at the time of enrolment. Subjects were assigned to one of three groups: SmartMouth Clinical DDS (SM), 0.12% chlorhexidine (CHX), or placebo (PL). Subjects were examined at 3 and 6 weeks. Data were evaluated as differences from baseline for each group. Analysis of variance (ANOVA), t tests or non-parametric alternatives were used to analyse data.
Results: The GI, BS and PI decreases from baseline were statistically significant at both 3 and 6 weeks for all three groups (p ≤ 0.025). Differences between groups were not statistically significant, except that the PI decrease for CHX was significantly greater than PL at 6 weeks (p = 0.048). At 6 weeks there was a statistically significant increase in TSI for CHX (p ≤ 0.001). CI decreased significantly for all groups at 3 weeks (p ≤ 0.004) and for PL at 6 weeks (p ˂ 0.001). At 3 weeks and 6 weeks, the percentages for compliance were significantly higher for SM and PL than for CHX (p ˂ 0.001). SM had less taste alteration reported than CHX (p = 0.003).
Conclusion: While all three groups were shown to improve GI, BS and PI scores; non-prescription SM resulted in less taste alteration, less tooth stain and better compliance than CHX.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3290/j.ohpd.a42504 | DOI Listing |
Int J Dent
April 2022
Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq.
Objective: This study aimed to evaluate and compare the force degradation of two types of elastomeric chains following different periods of immersion in zinc-containing mouthwashes.
Materials And Methods: Four hundred and forty pieces of Elasto-Force and Super Elasto-Force elastomeric chains were divided into two control and eight experimental groups. The pieces were stretched to 25 mm on pins mounted on an acrylic block and stored in distilled water at 37°C.
Purpose: To evaluate the efficacy of SmartMouth Clinical DDS compared with 0.12% chlorhexidine and placebo mouthrinses.
Materials And Methods: Seventy-six subjects with gingivitis or chronic periodontitis were enrolled in a double-blind, placebo-controlled, clinical study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!