A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spectrally fat-suppressed coronal 2D TSE sequences may be more sensitive than 2D STIR for the detection of hyperintense optic nerve lesions. | LitMetric

Objectives: The aim of the study is to compare coronal spectrally fat-suppressed 2D turbo spin-echo (TSE) with 2D short-tau inversion-recovery (STIR) sequences for the detection of optic nerve hyperintensities in patients with acute optic nerve neuritis (ON).

Methods: A retrospective review of patients with suspected unilateral ON and pathological visual evoked potentials, who received coronal TSE and STIR sequences with similar fast and clinically feasible acquisition times in addition to our standard imaging protocol. All images were evaluated and compared concerning the presence of optic nerve lesions, lesion lengths, and signal intensities in different anatomical parts of the optic nerves and CNR measures. A summary confidence score (CS) was calculated based on each reader's subjective confidence regarding the scoring items.

Results: Interobserver agreements regarding the detection of optic nerve lesions were excellent for both sequences (TSE, κ = 0.89 and STIR, κ = 0.80). Greater extensions (17.4 ± 6.3 mm vs. 14.1 ± 5.8 mm), as well as higher numbers of optic nerve lesions in symptomatic nerves, were detected on TSE (49/52) compared with STIR (45/52) sequences (both p < 0.001). Overall CS were significantly (p < 0.001) higher for TSE (2.8) compared with STIR (2.1) sequences regarding the presence or absence of optic nerve lesions. CNR ratios of lesions' mean signal intensities vs. ipsilateral surrounding orbital fat and vs. signal intensity measurements from contralateral optic nerves were significantly higher on TSE compared with STIR (p < 0.001 for both comparisons).

Conclusion: Spectrally fat-suppressed coronal 2D TSE sequences appear to be more sensitive for the detection of hyperintense optic lesions compared with 2D STIR sequences.

Key Points: • Spectrally fat-suppressed TSE sequences showed higher detection rates of hyperintense optic nerve lesions, as well as a higher reader confidence scores compared with STIR. • Optic nerve signal abnormalities on TSE sequences were brighter and showed a greater expansion along the optic nerve course. • CNR measures were significantly higher on TSE compared with STIR, when comparing the ratios of mean signal intensities of optic nerve lesions to ipsilateral orbital fat and to contralateral healthy optic nerves of both sequences.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-019-06255-zDOI Listing

Publication Analysis

Top Keywords

optic nerve
24
nerve lesions
16
spectrally fat-suppressed
8
coronal tse
8
stir sequences
8
detection optic
8
optic
7
nerve
6
tse
5
sequences
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!