A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Critical appraisal of MAPSE and TAPSE usefulness in the postoperative assessment of ventricular contractile function after congenital heart defect surgery in infants. | LitMetric

In this study, we assessed the adequacy of the two echocardiographic parameters representing the longitudinal systolic function of the ventricles, MAPSE & TAPSE, in perioperative monitoring. 1. The assessment of MAPSE and TAPSE during the early (4 weeks) postoperative period after surgical correction of congenital heart defects in infants, performed with CPB. 2. The verification of the hypothesis, that the significant decline of TAPSE observed in this period is not related to the global RV systolic dysfunction. For this reason, systolic function of the RV was additionally assessed with another echocardiographic parameter: RVFAC. Prospective study with 51 infants operated due to ASDII, VSD, AVSD and TOF. Four measurements of MAPSE,TAPSE and RVFAC were performed in the apical four-chamber projection. TAPSE and MAPSE were expressed as metric values and z-score; RV FAC values were expressed in percentages. TAPSE uniformly declined in the first postoperative day down to 34.5% of the initial value ( <0.00001), then gradually increased: up to 42.9% and 52% respectively, remaining significantly lower than preoperatively ( <0.001). RV FAC: increased by 21% ( <0.01), then remained stable in consecutive examinations. MAPSE declined by 21% during the first postoperative day, but with promptly normalized completely. The movement of both AV valve annuli is subjected to different, not fully understood influences. The relatively slight decline of MAPSE makes this parameter suitable for the assessment of the postoperative LV systolic function. Deep, long-lasting decline of TAPSE, uniform in the whole group, does not permit to use this parameter and suggests the choice of another one, e.g. RVFAC. In this study, we assessed the adequacy of the two echocardiographic parameters representing the longitudinal systolic function of the ventricles, MAPSE & TAPSE, in perioperative monitoring. 1. The assessment of MAPSE and TAPSE during the early (4 weeks) postoperative period after surgical correction of congenital heart defects in infants, performed with CPB. 2. The verification of the hypothesis, that the significant decline of TAPSE observed in this period is not related to the global RV systolic dysfunction. For this reason, systolic function of the RV was additionally assessed with another echocardiographic parameter: RVFAC. Prospective study with 51 infants operated due to ASDII, VSD, AVSD and TOF. Four measurements of MAPSE,TAPSE and RVFAC were performed in the apical four-chamber projection. TAPSE and MAPSE were expressed as metric values and z-score; RV FAC values were expressed in percentages. TAPSE uniformly declined in the first postoperative day down to 34.5% of the initial value ( <0.00001), then gradually increased: up to 42.9% and 52% respectively, remaining significantly lower than preoperatively ( <0.001). RV FAC: increased by 21% ( <0.01), then remained stable in consecutive examinations. MAPSE declined by 21% during the first postoperative day, but with promptly normalized completely. The movement of both AV valve annuli is subjected to different, not fully understood influences. The relatively slight decline of MAPSE makes this parameter suitable for the assessment of the postoperative LV systolic function. Deep, long-lasting decline of TAPSE, uniform in the whole group, does not permit to use this parameter and suggests the choice of another one, e.g. RVFAC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6750179PMC
http://dx.doi.org/10.15557/JoU.2019.0002DOI Listing

Publication Analysis

Top Keywords

mapse tapse
12
congenital heart
8
systolic function
8
tapse
6
critical appraisal
4
mapse
4
appraisal mapse
4
tapse postoperative
4
postoperative assessment
4
assessment ventricular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!