Extended delivery of non-steroidal anti-inflammatory drugs through contact lenses loaded with Vitamin E and cationic surfactants.

Cont Lens Anterior Eye

Lynthera Corporation, 1200 Corporate Blvd., STE 10C, Lancaster, 17601, PA, USA. Electronic address:

Published: October 2019

The purpose of this study is to extend drug release from ACUVUE Oasys® and ACUVUE TruEye® silicone hydrogel contact lenses by incorporation of vitamin E in conjunction with a cationic surfactant. In ACUVUE Oasys® and ACUVUE TruEye®, the release of ketorolac tromethamine and flurbiprofen sodium is extended from hours to several days for 11% and 21% vitamin E, (weight of vitamin E / weight of dry lens) but with a considerable reduction in the amount of drug released. Cetalkonium chloride and stearylamine increased the drug loading capacity which was otherwise compromised by the addition of vitamin E in the contact lenses. In the case of diclofenac sodium, a sustained release over 150 h for both contact lenses can be achieved. It was found that the release-time-increase factor due to vitamin E has a linear dependence with the octanol-water partition coefficient of the drug in ACUVUE Oasys®. The results in this study show that contact lenses loaded with vitamin E in conjunction with cationic surfactants achieved sustained release of non-steroidal anti-inflammatory drugs (NSAIDs) within the therapeutic window.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2019.04.011DOI Listing

Publication Analysis

Top Keywords

contact lenses
20
acuvue oasys®
12
non-steroidal anti-inflammatory
8
anti-inflammatory drugs
8
lenses loaded
8
loaded vitamin
8
cationic surfactants
8
oasys® acuvue
8
acuvue trueye®
8
vitamin conjunction
8

Similar Publications

Factors associated with eye disorders and diseases: A retrospective study.

Pak J Med Sci

January 2025

Olgun Goktas, Associate Professor, Uludag University Family Health Center, Nilufer, Bursa, Turkey.

Objective: To retrospectively identify the factors associated with eye disorders and diseases.

Methods: The retrospective study was carried out in Bursa Uludag University Family Health Center in Turkey between 1-30 September 2023. The data of individuals who were registered with the Family Health Center and whose eye disorders and diseases were known were evaluated retrospectively.

View Article and Find Full Text PDF

Purpose: To determine the performance of TOTAL30 for Astigmatism (T30fA; Alcon; Fort Worth, TX, USA) contact lenses (CLs) in existing CL wearers who are also frequent digital device users.

Methods: This 1-month, 3-visit study recruited adult, 18- to 40-year-old subjects who were required to use daily digital devices for at least 8 hours per day. All subjects were refit into T30fA CLs.

View Article and Find Full Text PDF

This study aims to build an optimal drug delivery system by manufacturing and evaluating a hydrogel contact lens using Tretinoin (ATRA) and protein nanoparticles to improve the drug delivery system as an ophthalmic medical contact lens. To evaluate the optical and physical properties of the manufactured lens, the spectral transmittance, refractive index, water content, contact angle, AFM, tensile strength, drug delivery, and antibacterial properties were analyzed. The contact lens was manufactured to contain ATRA and bovine serum albumin (BSA) in different ways, and the results confirmed that A, B, and C each had different physical properties.

View Article and Find Full Text PDF

Research Tendency and Frontiers of Multifocal Lenses in Myopic Control in the Past Two Decades: A Bibliometric Analysis.

Healthcare (Basel)

January 2025

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200031, China.

This study aimed to analyze the research progress on the use of a multifocal lens for myopic control throughout the 21st century, utilizing bibliometric analysis. Publications related to multifocal lenses from 2001 to 2024 were searched on the Web of Science core collection (WoSCC) database. VOSviewer (Version 1.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to compare the perception and understanding of the information provided by ChatGPT regarding myopia among optometry students, optometrists undertaking a Master degree and practicing optometrists.

Methods: This was a cross-sectional descriptive study using a structured questionnaire distributed via Wooclap to 225 participants (125 optometry students, 21 Masters students and 79 practicing optometrists). All participants evaluated the responses generated by ChatGPT Version 4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!