A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical and geometric characterization of peroneus longus allografts with respect to age. | LitMetric

Background: Anterior cruciate ligament injuries are among the most common injuries in high impact sports, and reconstruction is the standard surgical procedure for these ruptures. Reconstructions are often performed using allografts rather than autografts on a case-by-case basis. Controversy exists as to whether or not age of donor tissue plays a factor in the mechanical properties of allografts.

Methods: 38 peroneus longus (PL) tendons were prepared using the two-strand graft technique and then subjected to a cyclic loading test regimen of 1000 cycles to determine material properties. Specimens were grouped based on age to ascertain whether donor age affects the material properties of PL tendons.

Findings: Secant modulus of the first cycle was determined to be 150.43 (SD 40.24) MPa. The average magnitude of the dynamic modulus was determined to be 82.81 (SD 24.65) MPa. Specimens were grouped into three distinct groups for analysis (x < 40 yo, 40 yo ≤ x < 60 yo, 60 yo < x).

Interpretation: The need for using intrinsic material properties is highlighted. There is no significant difference in any intrinsic material property with respect to age or the fatigue of the tendon as the cycle count increases. Conversely, the measured stiffness of a tendon decreased as function of age with a large effect size. Based on analysis of graft geometries, it was determined that PL tendons become significantly more slender with increased age which result in the observed decrease in stiffness.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2019.04.017DOI Listing

Publication Analysis

Top Keywords

peroneus longus
8
material properties
8
specimens grouped
8
biomechanical geometric
4
geometric characterization
4
characterization peroneus
4
longus allografts
4
allografts respect
4
age
4
respect age
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!